Xylem Jabsco Ballast King 22610-9007 Скачать руководство пользователя страница 5

5

4.0 UNPACK AND CONTENTS

-  When unpacking the product ensure the correct 

unit is present. 

-  See ‘pump unit information’ for guidance on 

unit selection, information is displayed on the 
product label indicating which model you have.

Pump Unit Information:
-   22610-9007 – NPT Internal Ports, 12v, 30 minute 

cycle MAX.

-   22610-2007 – BSP Internal Ports, 12v, 30 minute 

cycle MAX.

Features
-   The pump has been designed to pump fluid 

into ballast tanks.

-   The pump is reversible so it can add liquid 

ballast, and then pump it overboard when 
needed.

-   When required, the pump is switched on to fill 

the tank then the pump switched off when full.

-   To reduce ballast, the pump will reverse to 

pump ballast back over board.

-   The same operation is used for ballast transfer 

between two tanks.

5.0 INSTALLATION

5.1 PUMP SET-UP

-  Verify that all components are present
-  Check the pump unit has not been damaged 

during transit

-  Ensure inlet and outlet ports are free from dirt, 

dust or packaging material

-  Ensure electrical data corresponds to those 

indicated on the product label and ensure 
the correct fuse is fitted in the power line (see 
section 8 for recommended fuses)

-  Fit a strainer on the inlet hose to prevent larger 

debris from entering the pump, ensure this is 
clean and free from dirt before use.

-  Before connecting the inlet and outlet hoses, 

ensure they are free from dirt. 

-  Secure 25 mm (1”) ID hose either directly to the 

discharge ports, or to ½” BSP/ NPT threaded 
fittings using stainless steel hose clamps.

-  Use spiral reinforced hose (with a smooth 

internal bore) that will not collapse under 
suction, or rigid or semi-rigid pipework systems.

-  The pump can be mounted on any flat suitable 

surface.

-  Fit the pump in a dry, well ventilated position 

where there is full access for service.

-  Use rubber grommets provided to minimise 

vibration, do not over tighten the mounting 
screws.

-  All marine pumps discharging overboard must 

be installed with the overboard discharge well 
above both static and heeled waterlines.

-

 The pipework must be compatible with liquid 

being pumped.

WARNING!
It is the installer’s responsibility to use hoses 
with suitable properties. The use of hose that is 
not suitable could cause damage to the pump, 
operator or the surrounding environment. 
The loosening of hose connections can cause 
environmental and safety issues. Check all 
connections after the initial installation and on 
a daily basis thereafter. Tighten if required. It 
is recommended the hose is installed prior to 
installing electrical supply.

WARNING!
Use a medium strength pipe sealant for metal 
threads.

- Pipe runs should be kept as straight as possible, 

avoiding rising and dipping over obstructions, 
shown below.

- In order to ensure good priming always keep 

connections tight. 

- Seal leaks should be checked and changed, as 

leakage could be dangerous, shown below.

- The pump should be installed so that the motor 

is protected from constant rain, wash down or 
bilge water.

- The pump should not be run with a closed outlet.
- Please note the pump body can be turned 180 

degrees in relation to the motor.  This will change 
the flow direction.

Install overboard discharge well above both 

static and heeled waterlines.

x x x x

Содержание Jabsco Ballast King 22610-9007

Страница 1: ...Ballast King DC Flexible Impeller Pump ...

Страница 2: ......

Страница 3: ...ectrical Configuration 5 4 Footprint Specifications 6 0 Environmental Protection 7 0 Product Operation 7 1 Operating Conditions 7 2 Permitted Fluids 7 3 Initial Start Up 7 4 Storage and Cleaning 8 0 Technical Specifications 9 0 Maintenance Service and Customer Repair 10 0 Customer Support 11 0 Parts and Accessories 12 0 EC Declaration of Conformity Ballast King DC Flexible Impeller Pump 3 ...

Страница 4: ...r safe operation when used as detailed in accordance with the Manufacturer s instructions This manual also contains necessary information for the correct installation This manual was developed for qualified personnel with suitable training and technical qualification to operate this type of equipment NOTE Failure to use this equipment in accordance with the manufacturer s operating instructions ma...

Страница 5: ... spiral reinforced hose with a smooth internal bore that will not collapse under suction or rigid or semi rigid pipework systems The pump can be mounted on any flat suitable surface Fit the pump in a dry well ventilated position where there is full access for service Use rubber grommets provided to minimise vibration do not over tighten the mounting screws All marine pumps discharging overboard mu...

Страница 6: ...rce see section 8 for recommended fuses Ensure fuses for the Ballast King pump are slow burning being capable of handling the start up and reversing current Connect the black motor wire to the negative battery terminal Inadequate voltage at the motor terminals when the pump is running not less than 95 below rated voltage at full load due to partially discharged batteries or insufficient cable size...

Страница 7: ...number is RM07081 Full details of scheme can be found Valpak Limited Unit 4 Montague House Stratford upon Avon Business and Technology Park Banbury Road Stratford upon Avon Warwickshire CV37 7GW At the end of your product and accessories life it must not be discarded as domestic waste Please contact your distributor supplier for further information For end users outside of the EU consult applicabl...

Страница 8: ... full enclose WARNING The working temperature of the motor may reach a maximum of approx 80 deg C surface temperature which may burn your skin Motors can spark and explosion and death can occur with incorrect wiring causing injury or death 7 4 STORAGE AND CLEANING If any pump unit needs to be removed for storage purposes it must be stored in a cool dry location Pump units are rated to IP55 It is r...

Страница 9: ... be returned please ensure the pump unit has been fully drained Please contact customer services for more information No used pumps parts will be accepted as returns unless complete details of liquids pumped are supplied Item Number Quantity Part Number 1 1 23094 9000 2000 2 1 98012 9334 3 1 9328 0200 4 2 X3001 147F 5 1 23095 0107 6 1 23005 2529 2530 7 1 SP2701 52 8 4 92900 0380 9 1 X5251 049 10 3...

Страница 10: ...me navigation and radio communication equipment and systems General requirements 2002 ELVD BS EN ISO 10133 Small craft Electrical systems Extra Low Voltage d c systems dc installations 2012 ISO ISO 8846 Small craft Electrical devices Protection against ignition of surrounding flammable gases 1990 ENV EN 60068 2 1 Cold 2007 EN 60068 2 2 Hot 2007 EN 60068 2 6 Vibration General 2008 Vibration Resonan...

Страница 11: ......

Страница 12: ... environment and we help people use water efficiently in their homes buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of innovation For more information on how Xylem can help you go to www xyleminc com UNITED STATES SA We...

Отзывы: