Xylem Jabsco Ballast King 22610-9007 Скачать руководство пользователя страница 10

10

12.0 EC DECLARATION OF CONFORMITY

Declaration of Conformity
In accordance with EN ISO 17050-1:2010

In accordance with the following Directive(s):
2004/108/EC 

Electromagnetic Compatibility 

2003/44/EC 

Recreational Craft Directive

2011/65/EU  

RoHS Directive (RoHS 2)  

ISO 8846   

Small craft Small craft - Electrical devices - 

 

 

Protection against ignition of surrounding flammable gases

hereby declare that:  Ballast King 12 V d.c. Flexible Impeller Pump

Equipment /  

22610-2007

Model number 

22610-9007

is in conformity with the applicable requirements of the following documents:

Directive

Reference Number

Title

Edition/Date

EMC

IEC 60945

Maritime navigation and radio communication 

equipment and systems. General requirements.

2002

ELVD

BS EN ISO 10133

Small craft – Electrical systems – Extra-Low-

Voltage d.c. systems .dc installations

2012

ISO

ISO 8846

Small craft -- Electrical devices -- Protection 

against ignition of surrounding flammable gases

1990

ENV

EN 60068-2-1

Cold

2007

EN 60068-2-2

Hot

2007

EN 60068-2-6

Vibration - General

2008

Vibration - Resonance

EN 60068-2-14

Cycling & Shock

2009

EN 60068-2-27

Shock & Bump

2006

EN 60068-2-30

Humidity

2005

EN 60068-2-31

Drop

2009

EN 60068-2-52

Salt Mist

2004

EN 60068-2-64

Vibration - Random

2008

RoHS

RoHS 2 deals with the 

same six hazardous 

substances and the same 

maximum concentration 

limits as RoHS 1

Lead   

 

                                  (0.1%)

Mercury                                                           (0.1%) 

Cadmium    

                                  (0.01%) 

Hexavalent chromium   

             (0.1%)

Polybrominated biphenyls [PBB]                (0.1%) 

Polybrominated diphenyl ethers [PBDE]  (0.1%)

2011

Содержание Jabsco Ballast King 22610-9007

Страница 1: ...Ballast King DC Flexible Impeller Pump ...

Страница 2: ......

Страница 3: ...ectrical Configuration 5 4 Footprint Specifications 6 0 Environmental Protection 7 0 Product Operation 7 1 Operating Conditions 7 2 Permitted Fluids 7 3 Initial Start Up 7 4 Storage and Cleaning 8 0 Technical Specifications 9 0 Maintenance Service and Customer Repair 10 0 Customer Support 11 0 Parts and Accessories 12 0 EC Declaration of Conformity Ballast King DC Flexible Impeller Pump 3 ...

Страница 4: ...r safe operation when used as detailed in accordance with the Manufacturer s instructions This manual also contains necessary information for the correct installation This manual was developed for qualified personnel with suitable training and technical qualification to operate this type of equipment NOTE Failure to use this equipment in accordance with the manufacturer s operating instructions ma...

Страница 5: ... spiral reinforced hose with a smooth internal bore that will not collapse under suction or rigid or semi rigid pipework systems The pump can be mounted on any flat suitable surface Fit the pump in a dry well ventilated position where there is full access for service Use rubber grommets provided to minimise vibration do not over tighten the mounting screws All marine pumps discharging overboard mu...

Страница 6: ...rce see section 8 for recommended fuses Ensure fuses for the Ballast King pump are slow burning being capable of handling the start up and reversing current Connect the black motor wire to the negative battery terminal Inadequate voltage at the motor terminals when the pump is running not less than 95 below rated voltage at full load due to partially discharged batteries or insufficient cable size...

Страница 7: ...number is RM07081 Full details of scheme can be found Valpak Limited Unit 4 Montague House Stratford upon Avon Business and Technology Park Banbury Road Stratford upon Avon Warwickshire CV37 7GW At the end of your product and accessories life it must not be discarded as domestic waste Please contact your distributor supplier for further information For end users outside of the EU consult applicabl...

Страница 8: ... full enclose WARNING The working temperature of the motor may reach a maximum of approx 80 deg C surface temperature which may burn your skin Motors can spark and explosion and death can occur with incorrect wiring causing injury or death 7 4 STORAGE AND CLEANING If any pump unit needs to be removed for storage purposes it must be stored in a cool dry location Pump units are rated to IP55 It is r...

Страница 9: ... be returned please ensure the pump unit has been fully drained Please contact customer services for more information No used pumps parts will be accepted as returns unless complete details of liquids pumped are supplied Item Number Quantity Part Number 1 1 23094 9000 2000 2 1 98012 9334 3 1 9328 0200 4 2 X3001 147F 5 1 23095 0107 6 1 23005 2529 2530 7 1 SP2701 52 8 4 92900 0380 9 1 X5251 049 10 3...

Страница 10: ...me navigation and radio communication equipment and systems General requirements 2002 ELVD BS EN ISO 10133 Small craft Electrical systems Extra Low Voltage d c systems dc installations 2012 ISO ISO 8846 Small craft Electrical devices Protection against ignition of surrounding flammable gases 1990 ENV EN 60068 2 1 Cold 2007 EN 60068 2 2 Hot 2007 EN 60068 2 6 Vibration General 2008 Vibration Resonan...

Страница 11: ......

Страница 12: ... environment and we help people use water efficiently in their homes buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of innovation For more information on how Xylem can help you go to www xyleminc com UNITED STATES SA We...

Отзывы: