Xylem Jabsco Ballast King 22610-9007 Скачать руководство пользователя страница 4

4

1.0 INTRODUCTION 

© The copyright of this instruction book is the 
property of XYLEM. This instruction book is 
supplied by XYLEM on the express understanding 
that it is to be used solely for the purpose for 
which it is supplied. It may not be copied, used 
or disclosed to others in whole or part for any 
purpose except as authorised in writing by XYLEM. 
XYLEM reserves the right to alter, change or 
modify this document without prior notification.

In the interest of continued development XYLEM 
reserves the right to alter or modify the design, or 
assembly process of their products without prior 
notification.

The Ballast King is a direct current (DC) electrical 
flexible impeller pump.  Depending on what 
model you have purchased (see section 4, Unpack 
and Contents), will determine what installations 
and what applications will be feasible for the pump 
you have purchased.

2. 0 SYMBOLS AND USING THIS INSTRUCTION 

BOOK

Caution, risk of danger. See note 
or adjacent symbol.

Caution hot surface 

Caution / risk of electric shock.

Recyclable packing material.

Do not dispose of product in normal 
domestic waste.

Refer to this instruction book.

3.0 SAFETY INFORMATION

WARNING!

Prior to installation or use, read this installation and 
operating instructions. Installation and operation 
must comply with local regulations and accepted 
codes of good practice.

Only used with specified products. DO NOT USE 
WITH LIQUIDS WITH A FLASH POINT BELOW 
100°F (38°C) OR USE WHERE FLAMMABLE 
VAPORS ARE PRESENT.

This product has been designed for safe operation 
when used as detailed in accordance with the 
Manufacturer’s instructions.

This manual also contains necessary 
information for the correct installation. 
This manual was developed for qualified 
personnel with suitable training and 
technical qualification to operate this type of 
equipment.

NOTE: Failure to use this equipment 
in accordance with the manufacturer’s 
operating instructions may compromise 
your basic safety protection afforded by the 
equipment and may invalidate the warranty 
/ guarantee. The warranty / guarantee 
does not cover damaged caused by faulty 
installation or misuse of the equipment. If 
the recommended safety notices are not 
strictly observed, it can lead to serious or fatal 
injuries of personnel and/or material damage.

Failure to observe the recommended safety 
procedures can lead to material damage.

Only qualified Service personnel should 
attempt to repair / service the product.

Do not immerse any part of this machine in 
water / fluid.

Do not operate the machine without 
appropriate piping attached. 

Do not run the machine without suitable 
supervision as established for safe working 
practices and company procedures. 

Not to be used by children and non-
authorized personnel.

Please keep this manual carefully and 
available to all operators.

Always follow good working practice when 
using this equipment.

Follow legislation applicable to your areas of 
operation. 

Do not touch the motor surface during or 
after operation of the pump as the surface can 
become hot.

Only use Original Equipment Manufacturer’s 
Parts and Accessories. 

The equipment is not spark, flame or 
explosion proof and has not been designed 
for use in hazardous areas in terms of the 
ATEX Directive 94/9/EC.
 

Содержание Jabsco Ballast King 22610-9007

Страница 1: ...Ballast King DC Flexible Impeller Pump ...

Страница 2: ......

Страница 3: ...ectrical Configuration 5 4 Footprint Specifications 6 0 Environmental Protection 7 0 Product Operation 7 1 Operating Conditions 7 2 Permitted Fluids 7 3 Initial Start Up 7 4 Storage and Cleaning 8 0 Technical Specifications 9 0 Maintenance Service and Customer Repair 10 0 Customer Support 11 0 Parts and Accessories 12 0 EC Declaration of Conformity Ballast King DC Flexible Impeller Pump 3 ...

Страница 4: ...r safe operation when used as detailed in accordance with the Manufacturer s instructions This manual also contains necessary information for the correct installation This manual was developed for qualified personnel with suitable training and technical qualification to operate this type of equipment NOTE Failure to use this equipment in accordance with the manufacturer s operating instructions ma...

Страница 5: ... spiral reinforced hose with a smooth internal bore that will not collapse under suction or rigid or semi rigid pipework systems The pump can be mounted on any flat suitable surface Fit the pump in a dry well ventilated position where there is full access for service Use rubber grommets provided to minimise vibration do not over tighten the mounting screws All marine pumps discharging overboard mu...

Страница 6: ...rce see section 8 for recommended fuses Ensure fuses for the Ballast King pump are slow burning being capable of handling the start up and reversing current Connect the black motor wire to the negative battery terminal Inadequate voltage at the motor terminals when the pump is running not less than 95 below rated voltage at full load due to partially discharged batteries or insufficient cable size...

Страница 7: ...number is RM07081 Full details of scheme can be found Valpak Limited Unit 4 Montague House Stratford upon Avon Business and Technology Park Banbury Road Stratford upon Avon Warwickshire CV37 7GW At the end of your product and accessories life it must not be discarded as domestic waste Please contact your distributor supplier for further information For end users outside of the EU consult applicabl...

Страница 8: ... full enclose WARNING The working temperature of the motor may reach a maximum of approx 80 deg C surface temperature which may burn your skin Motors can spark and explosion and death can occur with incorrect wiring causing injury or death 7 4 STORAGE AND CLEANING If any pump unit needs to be removed for storage purposes it must be stored in a cool dry location Pump units are rated to IP55 It is r...

Страница 9: ... be returned please ensure the pump unit has been fully drained Please contact customer services for more information No used pumps parts will be accepted as returns unless complete details of liquids pumped are supplied Item Number Quantity Part Number 1 1 23094 9000 2000 2 1 98012 9334 3 1 9328 0200 4 2 X3001 147F 5 1 23095 0107 6 1 23005 2529 2530 7 1 SP2701 52 8 4 92900 0380 9 1 X5251 049 10 3...

Страница 10: ...me navigation and radio communication equipment and systems General requirements 2002 ELVD BS EN ISO 10133 Small craft Electrical systems Extra Low Voltage d c systems dc installations 2012 ISO ISO 8846 Small craft Electrical devices Protection against ignition of surrounding flammable gases 1990 ENV EN 60068 2 1 Cold 2007 EN 60068 2 2 Hot 2007 EN 60068 2 6 Vibration General 2008 Vibration Resonan...

Страница 11: ......

Страница 12: ... environment and we help people use water efficiently in their homes buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of innovation For more information on how Xylem can help you go to www xyleminc com UNITED STATES SA We...

Отзывы: