Overload protection for variable-speed units
Variable-speed units have a single-point power panel with fuses for protection against
voltage spikes. In addition, the controllers have inherent features that protect the unit
against:
• short circuit
• undervoltage
• overload
• motor temperature
• dead heading
• run out
• suction loss
• sensor fault
• bound pump
• overvoltage
• static discharge
4.1.1 Field piping diagrams
AquaBoost VS simplex
1
2
3
4
5
6
7
8
10
9
RS000011
Typical field piping arrangement for the AquaBoost Variable Speed simplex pumping
package.
1. Anchor the pipe securely if vibration eliminators are used.
2. If a bypass line is installed, then this valve must be kept closed during normal operation. Do not install a
check valve.
3. Suction gauge, recommended
4. Optional tank
5. Discharge gauge
6. Vibration eliminator
7. 1/4 in. inlet tap on the check valve for low-suction pressure switch
8. Controller: AquaBoost II or Aquavar CPC
9. City supply
10.To system
_ _ _ _ Dashed lines indicate field installation.