7 Maintenance
Precautions
Before starting work, make sure that the safety instructions in the chapter
on page 3 have been read and understood.
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out power before
servicing to prevent unexpected startup. Failure to do so could result in death or serious
injury.
Equipment
locked
out
by
Name
.......................
DANGER
WARNING: Biological Hazard
Infection risk. Rinse the unit thoroughly with clean water before working on it.
CAUTION: Crush Hazard
Make sure that the unit cannot roll or fall over and injure people or damage property.
Make sure that you follow these requirements:
• Check the explosion risk before you weld or use electrical hand tools.
• Allow all system and pump components to cool before you handle them.
• Make sure that the product and its components have been thoroughly cleaned.
• Make sure that the work area is well-ventilated before you open any vent or drain
valves, remove any plugs, or disassemble the unit.
• Do not open any vent or drain valves or remove any plugs while the system is
pressurized. Make sure that the pump is isolated from the system and that pressure is
relieved before you disassemble the pump, remove plugs, or disconnect piping.
Precautions for handling permanent magnet synchronous motors
WARNING: Magnetic Hazard
Magnetic fields can damage cardiac pacemaker and other medical implants. Stay clear of
the permanent-magnet rotor, when disassembled from the motor.
WARNING: Electrical Hazard
The permanent-magnet motor generates voltage when the shaft rotates, even if power
sources are disconnected. Never perform any electrical work if the shaft could rotate.
7 Maintenance
6020.180/090 Installation, Operation, and Maintenance Manual
35