1. Turn off and lock out the power supply to the pump.
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out
power before servicing to prevent unexpected startup. Failure to do so
could result in death or serious injury.
Equipment
locked
out
by
Name
.......................
DANGER
2. Connect T3 and T4 from the motor cable of the pump to the USB dongle.
Only use isolated USB dongles that are recommended by the local sales and service
representative.
If T3 and T4 are connected to a gateway, then first disconnect the leads.
Terminal
Lead
TX+
T4
TX-
T3
3. Connect the USB port on the USB dongle to a USB port on the PC.
4. Turn on the PC and start the software application.
See
Run Dirigo
™
Service Tool
Make sure to take all necessary precautions and to follow all applicable requirements
before the power supply is turned on. See
1. In the software application, set the correct value for Com port under Control > Pump
communication.
See Control Panel > Device Manager for the correct value.
WS010158B
2. Turn on the power supply to the pump.
The pump starts to operate directly.
WARNING: Crush Hazard
Moving parts can entangle or crush. Make sure nobody is close to the
unit when it is started.
3. Select Connect.
The software application starts to communicate with the pump and the pump stops.
8 Troubleshooting
6020.180/090 Installation, Operation, and Maintenance Manual
49