An optional stainless steel protection hose can be used to protect the motor cable. To
prevent leakage, use thread tape when mounting the hose into the gland screw.
1. Check the data plate to see which connections are required for the power supply:
• Y
• D
• Y serial
• Y parallel
• Y/D
2. Arrange the connections on the terminal board in accordance with the required power
supply.
Do not use links (jumper strips) with the Y/D start.
Do not use links (jumper strips) with the 9 stator leads tandem-coupling.
3. Connect the motor conductors (U1, V1, W1, and earth (ground)) to the terminal board.
4. Make sure that the pump is correctly connected to earth (ground).
5. Make sure that any thermal contacts incorporated in the pump are properly connected
to the terminal board.
6. Install the cover.
7. Fasten the screws on the entrance flange so that the cable insertion assembly bottoms
out.
After you have connected the motor cable to the pump, connect the motor cable and the
control cable to the starter equipment.
WARNING:
Do not install the starter equipment in an explosive zone unless it is explosion-proof rated.
Three thermal contacts are incorporated in the stator. They are normally closed.
Thermal contacts must never be exposed to voltages higher than 250 V, breaking current
maximum 6 A at a power factor 0.6. It is recommended that the thermal contacts are
connected to 24 V over a separate fuse to protect any other automatic equipment.
Installation
18
Flygt 3060 Installation, Operation, and Maintenance Manual
Содержание Flygt 3060
Страница 1: ...Flygt 3060 Installation Operation and Maintenance Manual ...
Страница 2: ......
Страница 41: ...Figure 7 MT CP DP Technical Reference Flygt 3060 Installation Operation and Maintenance Manual 39 ...
Страница 42: ...Figure 8 HT CS Technical Reference 40 Flygt 3060 Installation Operation and Maintenance Manual ...
Страница 43: ...Figure 9 MT CS DS Technical Reference Flygt 3060 Installation Operation and Maintenance Manual 41 ...
Страница 48: ......
Страница 49: ......