94
16
117
85
94
98 23
24
23
19 22
20
21
66
31
110
136
WS001321A
Part
Description
16
Cover
21
Nuts
31
Gland nut
Figure 3: Cable entry
1. Check the data plate to see which connections are required for the power supply:
• Y
• D
• Y serial
• Y parallel
• Y/D
2. Arrange the connections on the terminal board in accordance with the required power
supply.
Do not use links (jumper strips) with the Y/D start.
Do not use links (jumper strips) with the 9 stator leads tandem-coupling.
3. Connect the motor conductors (U1, V1, W1, and earth (ground)) to the terminal board.
4. Make sure that the pump is correctly connected to earth (ground).
5. Make sure that any thermal contacts incorporated in the pump are properly connected
to the terminal board.
6. Install the cover.
7. Fasten the nuts and the gland nut on the entrance flange so that the cable insertion
assembly bottoms out.
After you have connected the motor cable to the pump, connect the motor cable and the
control cable to the starter equipment.
Installation
16
Flygt 2250 Installation, Operation, and Maintenance Manual