11.Repeat steps 1-10 for the inboard side of the pump.
12.Assemble the stationary face of the mechanical seal to the seal gland using its
alignment pins as a guide.
13.Place the seal gland O-ring into its respective groove.
14.Slide the seal gland and stationary mechanical seal element assembly onto the shaft.
Secure the seal gland to the stuffing box using with correctly sized hex head bolts and
lockwashers.
15.Thread the external flush line fitting into the top of the seal gland.
16.Repeat for the inboard side of the pump.
17.Install stuffing box pins into each stuffing box.
18.Ensure pins are installed into each casing wear ring. Align casing wear ring pins to
their respective grooves within the lower casing.