The width of the pump foundation should be wider than the extended 30° lines.
When viewing the pump from the end of the base plate establish a vertical line through
the pump shaft center. On both sides of this vertical line a line that starts at the pump shaft
center and extends downward at 30°. These lines must pass through the bottom of the
foundation.
Pumps on Spring Isolation Bases
• Spring mounting isolates the vibration from a pump from the floor or the foundation it
is mounted on. Spring mounting can absorb piping loads from thermal expansion or
reactions to internal pressure for properly supported piping systems. Be sure to
anchor the piping before mounting to the pump.
• The pump unit can be installed on a spring isolated base. The spring isolators are not
to be installed directly to the pump base plate given. The entire unit must be put on an
isolation base that has the spring mounts attached to it. These isolation bases are
welded structural steel with reinforcing and are filled with concrete or grout. The
design requirements and installation of these isolation bases are the responsibility of
the installing contractor.
• Use flexible piping on both suction and discharge sides with an isolation base. Flexible
piping decreases the strain on the flanges.
Anchor bolts
• Foundation bolts or anchors of the proper size and type must be used. Foundation
bolts that are cast in place can be of either type shown in pump detail figure. Concrete
anchors can also be used. The type selected must be consistent with local codes.
• The size of the foundation bolts or anchor should be 1/8” (3 mm) smaller diameter
than the holes provided in the base plate. Refer to the pump submittal for the quantity
and size.
1
2
3
4
5
1. Foundation bolt
2. Pipe sleeve
3. Concrete foundation
4. Washer
5. Lug
Anchor bolt and hole sizes
• As a rule, the diameter of the anchor bolt hole should be 0.125 in (3 mm) larger than
the diameter of the anchor bolt.
4 Installation
e-XC INSTRUCTION MANUAL
19
Содержание e-XC
Страница 1: ...INSTRUCTION MANUAL P6019152 e XC Single Stage Double Suction Centrifugal Pumps ...
Страница 2: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......