![Xylem e-XC Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/xylem/e-xc/e-xc_instruction-manual_4055752023.webp)
• Make sure that the shim thickness is at least 0.06 in. (1.52 mm) thick. If the base is
grouted then the shims need to be thicker.
• Make sure that the base is anchored to the foundation with bolts in all rail foundation
holes. Optionally, you can place shims under the rail between the rail mounting bolts.
Piping check
Do not pipe the pump until it is realigned.
After piping is completed and after the pump is installed and bolted down, align it again.
You might need to re-adjust the alignment on a few occasions while the unit and
foundation are new.
Grouting
Grout the baseplate after the pump unit has been leveled, securely bolted to the floor,
and properly aligned. Use a high precision non-shrinking grout inside the pump
baseplate.
4.2 Level the base on a concrete foundation
Place 1.00 in./(25.40 mm) thick steel shims or wedges on both sides of each anchor
bolt in order to support the pump .
This also provides a means of leveling the base.
4
1
5
2
3
6
7
1. Locate the shims to allow removal after grouting.
2. Grout only to top of base rail
3. Pump base rail
4. Grout
5. Concrete foundation
6. 1” (25.40 mm) Gap
7. Allow 1” for shims. Place on both sides of anchor bolts.
4.3 Coupling alignment
WARNING:
Always disconnect and lock out power to the driver before you perform any installation or
maintenance tasks. Failure to disconnect and lock out driver power will result in serious
physical injury.
Alignment guidelines
Follow these guidelines when you align the coupling:
• Only perform alignment by moving or shimming the motor.
• Since adjustments in one direction can alter the alignment in another direction, check
the alignment in all directions after you make a correction.
• Make sure that the pump and motor bolts are tight when you take all measurements.
• Perform a final alignment check after the unit reaches its final operating temperature.
4 Installation
e-XC INSTRUCTION MANUAL
21
Содержание e-XC
Страница 1: ...INSTRUCTION MANUAL P6019152 e XC Single Stage Double Suction Centrifugal Pumps ...
Страница 2: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......