XVME-202 Manual
December, 1986
Chapter 2
INSTALLATION
2.1 INTRODUCTION
This chapter explains how to configure the XVME-202 PAMUX Interface Module
prior to installation in a VMEbus backplane. Included in this chapter is information
on module base address selection jumpers, address modifier jumper, connector
pinouts, and a brief outline of the physical installation procedure.
2.2 SYSTEM REQUIREMENTS
The XVME-202 PAMUX Interface Module is a single high VMEbus compatible
module. To operate, it must be properly installed in a VMEbus backplane.
The minimum system requirements for the operation of an XVME-202 PAMUX
Interface Module are one of the following:
A)
-
A host processor properly installed on the same backplane.
A properly installed system controller module which provides the
following functions:
--
Data Transfer Bus Arbiter
- -
System Clock driver
- -
System Reset driver
--
Bus time-out module
An example of such a controller subsystem is the XYCOM XVME-010 System
Resource Module (SRM).
B)
l
A host processor which incorporates the system controller functions
on-board.
An example of such a processor is the XVME-600 or the XVME-601.
Prior to installing the XVME-202 PAMUX Interface Module, it will be necessary to
configure three jumper options. These options are:
1)
Module base address within the short I/O address space.
2)
Address Modifier codes to which the Module will respond.
3)
Select SYSCLOCK or on-board Oscillator.
2 - 1
Содержание XVME-202
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 16: ......
Страница 19: ......
Страница 21: ......
Страница 22: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......