background image

1 142027(G) 

1. Product Overview 

Pro-face/Xycom industrial monitors meet the rigorous requirements of the plant floor 
with high-resolution flat panel displays in a rugged housing with an optional resistive 
membrane touchscreen. The XT1502 flat panel monitor delivers crisp, bright text and 
graphics with a low current draw, and it fits into panels that CRTs cannot. 
 
The XT1502 is self-contained, requiring only to be panel mounted in an appropriate 
enclosure and connected to 120/240 VAC and VGA source. 

 
 

 
 

Standard XT1502 Features

 

 

15.0" bright (200 Nit), easy-to-read, high contrast (150:1), color (6 bit/262,144 

 

colors) TFT flat panel display with SVGA (1024x768) resolution 

 

Large viewing area and viewing angles (120° horizontal, 100° vertical) 

 

Operator input through an optional integrated high-performance (35 million touch) 
touchscreen 

 

Front panel controls with onscreen menus (lock switch on rear of units) 

 

Long-lasting (50,000 hour) backlight 

 

Hinged design for easy backlight field replacement 

 

Simple mounting 

 

Shallow mounting depth 

 

Up to 50 foot cables 

 

Optional 19" EIA rackmount adapter plate 

 

NEMA 4/12 front panel, when properly mounted 

 

UL and cUL recognized, CE marked 

 

Units ship with all necessary cables and software            

 

 
              

 

When you remove the XT1502 from its shipping carton, verify that you have the parts 
listed below. Save the box and inner wrapping in case you need to reship the unit. 

 

 Standard XT1502 Parts List 

 

XT1502 unit. 

 

Ten-foot VGA cable. 

 

Ten-foot serial cable (touchscreen units only). 

 

Documentation and Support Library CD-ROM. In addition to containing this manual, 
this CD contains all drivers required by this unit (touchscreen drivers in the case of 
XT1502T units). 

 
 
 
 
 
 

Product Features 

Parts List 

Содержание XT1502

Страница 1: ...1 142027 G XT1502 FLAT PANEL INDUSTRIAL MONITOR FLAT PANEL INDUSTRIA Hardware Guide...

Страница 2: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipme...

Страница 3: ...nsiderations 5 System Power 5 Excessive Heat 5 Electrical Noise 6 Line Voltage Variation 6 Location and Enclosure 7 Panel Installation 7 Panel Mounting Dimensions 7 3 Monitor Settings 8 Mode and Image...

Страница 4: ...through an optional integrated high performance 35 million touch touchscreen Front panel controls with onscreen menus lock switch on rear of units Long lasting 50 000 hour backlight Hinged design for...

Страница 5: ...red by the user will appear in a monospace font Operator interfaces such as the Start menu button and keyboard keys such as Enter appear in a narrow bold typeface Other text such as the word Note is b...

Страница 6: ...n mm Front Panel Controls The front panel controls from left to right are Menu Select Increment Decrement Their use is detailed in Chapter 3 Monitor Settings Product Dimensions 16 48 418 6 3 25 82 60...

Страница 7: ...0 Hz 0 006 peak to peak displacement 1 0 g maximum acceleration 0 015 peak to peak displacement 2 5 g maximum acceleration Altitude Sea level to 10 000 ft 3 000 m Sea level to 40 000 ft 12 000 m Elect...

Страница 8: ...the following practices Separate the power and ground P E or Protective Earth cable from signal cables at the point of entry to the enclosure To minimize the ground wire length within the enclosure lo...

Страница 9: ...its operating margin As long as the incoming voltage is adequate the power supply provides all the logic voltages necessary to support the monitor unit Unusual AC line variations may cause undesirabl...

Страница 10: ...nt Avoid overloading the supply circuit This monitor should be mounted in and used where NEMA 4 and NEMA 12 type enclosures are employed When mounted properly the monitor meets or exceeds the sealing...

Страница 11: ...l panel to the following choices Colors 256 Vertical Refresh 60 Hz Resolution 1024 x 768 Monitor Type Viewsonic 15 Note The monitor type option is not available in Windows NT Once the monitor is power...

Страница 12: ...positions size tuning etc Press to activate auto setup Image Adjust Turns on the Image Adjust submenu Pressing turns on the Image Adjust menu OSD Menu Turns on the OSD submenu Pressing turns on the O...

Страница 13: ...turns on table 1 Direct Access 2 Turn on direct access table 2 Pressing turns on table 2 Language Select OSD language Pressing turns on the submenu in English Direct Access 1 2 Submenu Menu Option De...

Страница 14: ...From the resulting page you can download the User Manual and or the touch screen driver 4 Click on the link to elo zip the drivers for all of the operating systems are in this file Type a destination...

Страница 15: ...ews that hold the back of the monitor on 3 Separate the two halves of the monitor If the unit is equipped with a touchscreen you will have to disconnect its cable 4 The lamps are mounted in small plas...

Страница 16: ...nly one orientation 9 You may now want to clean the LCD and the inside of the monitor window or touchscreen with a slightly damp soft cloth 10 Carefully reunite the two monitor halves remembering to r...

Страница 17: ...from the Microsoft Diagnostic utility MSD or other diagnostic applications 5 Details of attempts made to rectify the problem s and results 6 The log number assigned from Pro face Technical Support if...

Страница 18: ...ht WEIGHT 19 lbs I O A A B B SECTION B B SECTION A A 6 77 9 72 11 17 8 22 5 26 10 32 6 PLACES 3 15 4 84 11 64 2 93 1 39 VGA TOUCH POWER ENTRY REAR AND SIDE VIEW FRONT PANEL CONTROLS DISABLE XT1500 ENC...

Страница 19: ...142027 G Xycom Automation LLC 734 429 4971 Fax 734 429 1010 750 North Maple Drive http www profaceamerica com Saline MI 48176...