background image

KPM(T) Series Flat Panel Industrial Monitor

                                                 Chapter 5 – Keypad Utility Program 

 

39 

   143448 (

D

 

A full-stroke keyboard is needed to enter keystrokes while recording a new key 

macro, editing an existing macro, or entering utility commands. You can redefine all 

keys on the keypads, except the F/A (Function/Alpha) key. While the utility is 

running, the keypads are disabled. 

Dialog boxes appear for user prompts, and to display error and user advice messages. 

Any keys used specifically in each menu are shown at the bottom of each screen (see 

Figure 5-1). 

Two keys allow you to exit the menus: 

• 

ESC 

moves to the previous menu or out of the utility from the Main Menu 

• 

F1 

returns to the current menu headings in some of the menus where 

Exit

 can 

be chosen to exit this menu 

Startup 

To begin using the keypad utility, type 

kp3util

 at the prompt (for the floppy drive 

when no DOS is available, or the subdirectory you created earlier). The program will 

bring up the main menu. Open the 

def3612.pkm

 file in the main menu to program the 

keypad. (This file contains the default keypad settings for the KPM(T) monitors.) 

Changes to the default file should be saved to a new file with the pkm extension. If 

you do not open a file, the macros pull-down menu will not be available. 

Note 

If you make any changes to your keypad and want to set it back to the default settings, 

open the pkm file for your unit (e.g., def3612.PKM for 5015KPM) from the File/Open 

menu, and then download it from the download menu.  

Caution 

Do not save any changes to the default files. 

Main Menu 

Figure 5-1 shows the Main Menu screen. The functions of the pull-down menus are 

described in the following sections. 

Note 

     Exit and Download do not have pull-down menus.  

Note 

     Use 

F

1 to access the menu bar options in the 

kp3util

 program.  

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание KPM Series

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...ted in the United States of America KPM T Monitor Series Flat Panel Industrial Monitors User Manual for the 5012KPM T and 5015KPM T models Artisan Technology Group Quality Instrumentation Guaranteed 8...

Страница 3: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of t...

Страница 4: ...s I Locations 25 Class II Locations 25 Division 1 Locations 25 Division 2 Locations 26 Groups 26 Enclosures 27 Power Switch 27 Cable Connections 28 Hazardous Locations Control Drawing 29 Operation and...

Страница 5: ...ANEL FRAME 50 Chemicals Compatible with Frame 50 Front Panel Overlay 51 Chemicals Compatible with Overlay 51 Compatible Cleaning Agents for Overlay 51 Chemicals Not Compatible with Overlay 51 APPENDIX...

Страница 6: ...ed for Hazardous Locations Class I Division 2 Groups A B C Class II Division 2 Groups F and G pending Standard Features The KPM T monitor comes with the following standard features Rear IBM PS 2 keybo...

Страница 7: ...and back panels to help you locate the features of the KPM T monitors Figure 1 1 shows the front panel controls for the KPM T monitors Table 1 1 outlines the front panel control functions Figure 1 1 5...

Страница 8: ...tenance Diagnostic LEDs Following is a description of the diagnostic LEDs and their meanings Power GREEN when the system has power Disk LED is not active on the 5012KPM T and 5015KPM T COM LED is not...

Страница 9: ...d control keys 40 relegendable function keys All keys reprogrammable except the F A key Integrated Mouse The 5012KPM T 5015KPM T feature a 2 button integrated mouse See Chapter 5 Keypad Utility Progra...

Страница 10: ...15KPM T Back Panel bottom view The back panel contains the OSD controls the power connector a video input connector a pass thru USB port B style connector the serial touchscreen output connector and t...

Страница 11: ...A port 9 AC Input DC option 100 240 VAC auto ranging 18 30 VDC on DC models See diagrams on previous page USB devices plugged directly into this connector will not function The OSD controls are explai...

Страница 12: ...will connect a cable to both the AC port and the Video In port The cable from the computer to the Video In port provides the signal connection for the monitor An RS 232 cable sends touch screen signa...

Страница 13: ...keyboard to the keyboard port 2 Attach optional mouse to the mouse port 3 Attach other optional equipment following the instructions in Chapter 2 4 Attach the power cord from the power receptacle to...

Страница 14: ...ith all the safety requirements 1 Select a NEMA rated enclosure and place the unit within the enclosure to allow easy access to the system ports see other sections in this chapter and Appendix A To as...

Страница 15: ...d other harmful contaminants from entering the enclosure Do not select a location near equipment that generates excessive electromagnetic interference EMI or radio frequency interface RFI Examples of...

Страница 16: ...tout Dimensions Figure 2 1 shows the cutout dimensions for the 5012KPM T Figure 2 2 shows the cutout dimensions for the 5015KPM T 5012KPM T Figure 2 1 5012KPM T system cutout dimensions inches mm Arti...

Страница 17: ...Panel Industrial Monitor Chapter 2 Installation 12 143448 D 5015KPM T Figure 2 2 5015KPM T system cutout dimensions inches mm Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Страница 18: ...be permanent no solder continuous and able to safely conduct the ground fault current in the system with minimal impedance minimum wire required is 18 AWG 1 mm Observe the following practices Separat...

Страница 19: ...hazardous machine operation in certain applications Noise may be present only at certain times may appear at widely spread intervals or in some cases may exist continuously Noise commonly enters thro...

Страница 20: ...ed at any time without affecting the host It is the initial power up of the host that requires the power up sequence If an operating system is loaded on the host computer the KPM T monitor should not...

Страница 21: ...or higher The Pro face Xycom BIOS revision number will appear at the top of the screen briefly during system boot up If you do not see the Pro face Xycom BIOS revision number for the CPU module enabl...

Страница 22: ...nsions are in inches mm Recommended material 0 007 0 176 thick polyester with 3M 468 adhesive on far side 0 06 1 52 4 Places Figure 2 5 Logo Label Dimensions Creating Custom Keypad Inserts You can cus...

Страница 23: ...ypad Inserts The following figures show the dimensions for the 5012KPM T keypad inserts Figure 2 6 5012KPM T Keypad Inserts with Dimensions PF1 PF10 Note The PF11 PF20 insert has the same dimensions A...

Страница 24: ...lat Panel Industrial Monitor Chapter 2 Installation 19 143448 D Figure 2 7 5012KPM T Keypad Insert with Dimensions F1 F20 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 25: ...ypad Inserts The following figures show the dimensions for the 5015KPM T keypad inserts Figure 2 8 5015KPM T Keypad Inserts with Dimensions PF1 PF10 Note The PF11 PF20 insert has the same dimensions A...

Страница 26: ...lat Panel Industrial Monitor Chapter 2 Installation 21 143448 D Figure 2 9 5015KPM T Keypad Insert with Dimensions F1 F20 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 27: ...Keypad Installation Diagram The following figure shows how to insert the custom keypads you have created Figure 2 10 Rear View of KPM T Monitor Bezel with Keypad Insertion Points Marked Artisan Techno...

Страница 28: ...y devices attached to this equipment in Division 1 locations Note When additional cards are added it is the customer s responsibility to ensure that the cards chosen meet operating conditions for Clas...

Страница 29: ...142 Process Control Equipment cUL Listed File E107636 Warning Suitable for use in Class I Division 2 Groups A B C and D and Class II Division 2 Groups F and G Hazardous Locations or non hazardous loc...

Страница 30: ...ensuring that all relevant codes and regulations related to location rating enclosure and wiring are met Class I locations are those in which flammable gases or vapors are or may be present in the air...

Страница 31: ...ons are normally insufficient to interfere with normal operation of electrical equipment or other apparatus Combustible dust may be in suspension in the air as a result of the following malfunctioning...

Страница 32: ...ensure that the installation is compliant with codes and regulations that apply to their specific location Refer to NFPA 70 Article 500 for specific regulations in the United States The KPM T monitor...

Страница 33: ...the ground shield braid should be well terminated directly to the connector housing Do not use a shield drain wire The outer diameter of the cable must be suited to the inner diameter of the cable co...

Страница 34: ...Wiring Apparatus shall satisfy the following Nonincendive Field Wiring Apparatus Pro face Xycom Models 5012KPM T and 5015KPM T Vmax Voc Imax Isc Ci Ccable Ca Li Lcable La 3 If the electrical paramete...

Страница 35: ...ion installations always observe the following rules 1 Always install the workstations within an enclosure suitable for the specific application General purpose enclosures may be acceptable for Class...

Страница 36: ...ll video controllers produce exactly the same video output levels or the same timing The KPM T monitors use onscreen configuration menus to make setup and adjustment easy The menus are selected and th...

Страница 37: ...OSD Timeout submenu under Miscellaneous Figure 3 2 OSD Functions menu Press MENU to select the highlighted adjustment menu the first adjustment option in the menu will be highlighted Use INC or DEC t...

Страница 38: ...in the submenus for the color menu the RGB menu the position menu the image menu and the miscellaneous menu Note In the following tables the INC button is referred to as and the DEC button is referred...

Страница 39: ...menu and highlight Load Default 2 Press SELECT to enter submenu which will ask you to choose yes or no 3 Press the INC key to highlight yes and press SELECT to enable your choice 4 The default settin...

Страница 40: ...Modes NOTE All video modes are non interlaced If the monitor is receiving timing signals that are not compatible OUT OF TIMING will appear Follow your computer s instruction manual to set the timing...

Страница 41: ...th a mouse and touch screen are to be supported For computers running MS DOS you will be installing the driver This driver can be found in the Drivers Touchscreen folder on the Documentation and Suppo...

Страница 42: ...the edges of the screen causing the cursor to jump unexpectedly 5 Click on the Settings tab 6 Set the Averaging to 0 7 Click Apply You are now ready to calibrate your touch screen Follow the instructi...

Страница 43: ...ntation Support Library CD that shipped with your computer You will find the self extracting zip file Keypad Utility 1 1 142606 001 exe in the folder DRIVERS Keypad Software Keypad Utility 1 1 142606...

Страница 44: ...the floppy drive when no DOS is available or the subdirectory you created earlier The program will bring up the main menu Open the def3612 pkm file in the main menu to program the keypad This file co...

Страница 45: ...ten Once loaded the macro set is available to edit view teach or download to the keyboard controller Close Clears the macro set from memory and closes the file from which the set came Save Copies the...

Страница 46: ...hosen the Exit option is displayed on the menu bar and a graphic representation of the chosen keypad is shown To return to the Macros Menu select Exit from the View Menu To select a key to view use th...

Страница 47: ...Macros menu Click OFF is not supported To select a key to edit use the arrow keys to position the cursor on the desired key and press ENTER In edit mode the macro is displayed as two lines The top li...

Страница 48: ...press ENTER Codes displays a table of keys and their scan codes in Hex See the Codes section in this chapter for a complete code listing Hex Decimal toggles between displaying the scan codes in Hex a...

Страница 49: ...Description Factory Default Reprograms the keypad macros to the factory default settings After completion the system will need to be power cycled Exit Returns to the Main Menu Utility Batch Mode The U...

Страница 50: ...LED On Alpha Mode Description of Key Keyboard Equivalent Make Codes Break Codes Keyboard Equivalent Make Codes Break Codes PF1 A F21 14 05 F0 05 F0 14 A 1C F0 1C PF2 B F22 14 06 F0 06 F0 14 B 32 F0 32...

Страница 51: ...F0 0B F0 11 12 25 F0 12 F0 25 PF17 F37 11 83 F0 83 F0 11 12 1E F0 12 F0 1E PF18 F38 11 0A F0 0A F0 11 12 41 F0 12 F0 41 PF19 F39 11 01 F0 01 F0 11 12 49 F0 12 F0 49 PF20 F40 11 09 F0 09 F0 11 12 0E F...

Страница 52: ...n arr E0 12 E0 72 E0 F0 72 E0 F0 12 down arr E0 12 E0 72 E0 F0 72 E0 F0 12 2 7B F0 7B 7B F0 7B ENTER ENTER 1 5A F0 5A ENTER 5A F0 5A END END E0 12 E0 69 E0 F0 69 E0 F0 12 END E0 12 E0 69 E0 F0 69 E0 F...

Страница 53: ...n area Check the connections to I O modules especially in environments where vibration could loosen the connections Check to see that all plugs sockets terminal strips and module connections are solid...

Страница 54: ...ance operating specifications Pro face tests products returned to Pro face with the standard Pro face test diagnostics Follow the steps below to prepare the unit for shipment 1 Obtain a Return Merchan...

Страница 55: ...drocarbons G F Benzoic Sodium Hydroxide P P Chlorinated Hydrocarbons P N Boric Ketones F P Butyric 100 Aluminum Sulfate E E Ethers F P Chloracetic 10 Ammonium Chloride E E Esters F P Chromic 5 Copper...

Страница 56: ...id 30 Hydrochloric acid 10 Nitric acid 10 Sulphuric acid 10 Sodium hypochlorite 20 Hydrogen peroxide 25 Potassium carbonate Washing powders Fabric conditioner Ammonia 2 Caustic soda 2 Alkalicarbonate...

Страница 57: ...protrusion 1 00 in 25 4 mm 18 85 lbs 8 55 kg Electrical AC Power DC Power 100 240 V AC 1A maximum 50 60 Hz 18 32 V DC Front Panel NEMA 4 4X 12 and IP65 Agency Approvals UL 508 Listed Industrial Contr...

Страница 58: ...to 80 RH non condensing 20 to 80 RH non condensing Altitude Operating Non operating Sea level to 10 000 feet 3 048 m Sea level to 40 000 feet 12 192 m Vibration 5 2000 Hz Operating Non operating 0 006...

Страница 59: ...B 15 connector Table B 1 VGA Input Connector Pinout D Shell Female Signal Name 1 Red 2 Green 3 Blue 4 5 GND Digital 6 GND Red return 7 GND Green return 8 GND Blue return 9 DDC 5V 10 GND Digital 11 12...

Страница 60: ...ion RTS and DTR are connected together inside the KPM T monitors Note The KMP T monitor has been configured to use a straight through cable to connect the monitor to the PC USB Input Output Connector...

Страница 61: ...rt 3 Keypad inserts custom 16 Keypad Inserts 17 19 Keypad keycodes default 43 Keypad utility Batch Mode 42 Download menu 41 Exit menu 38 Files menu 38 loading 36 Macros Keypad Type Menu 38 Main menu 3...

Страница 62: ...1 Fax 734 429 1010 http www profaceamerica com Canada Sales 905 607 3400 Northern Europe Sales 44 1604 790 767 Southern Europe Sales 39 011 770 53 11 Artisan Technology Group Quality Instrumentation G...

Страница 63: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: