39
Microtouch Controller
If you need to recalibrate the touchscreen, refer to the sec-
tions in the touchscreen manual that explain calibrating the
touchscreen and using the diagnostic utility.
Note
The touchscreen and controller are a
matched pair calibrated at the factory.
Xycom Controller
If you need to recalibrate the touchscreen, run the Pointer
Devices Control Panel applet. Select Help for details about
calibrating. For best results, use the 25 point calibration
setting with Start In At set to 0.
You need to calibrate the touchscreen if
•
The cursor does not follow the movement of your finger or pen
•
You adjust the size of the video image or change the video mode
Creating a Power Cable
This section describes how to create both an AC and a DC power cable.
AC Power Cable
You must create an AC power cable to supply power to units with AC power supplies.
You will need the following materials:
•
A three-position power connector (supplied)
•
A braid/foil shielded power cable, terminated at power source end, with three 18 (1.0
mm), 16 (1.3 mm), or 14 (1.6 mm) AWG solid or stranded copper wire, rated 80º C
or better.
Perform the following steps to create the cable:
1.
Cut the wire cable to the desired length.
2.
Strip 0.25-inch (6 mm) of insulation from the end of the conductor wire. No bare
wire should be exposed when the cable is connected to the workstation.
3.
Tin the wire ends with solder if using stranded wire. This will keep the wire from
fraying.