background image

 

25 

8

 

APPENDIX  Ⅱ ABOUT RS485 BUS 

8.1

 

RS485 Bus Main Feature  

RS485 is semi duplex communication cable of impedance 120

Ω

. Its max load amount is 32 

effective loads (including main control device and devices to be charged). 

8.2

 

RS485 Bus Transmission Distance 

When we take 0.56mm (24AWG) twisted-pair as communication cable, the max  transmission 

distance (theoretically) are listed below (according to different baud rates). 

 

 
 

 

In the following situations, the max transmission distance shall become short er accordingly: 

 

The communication cable is a little bit thin; 

 

The surrounding environment has strong electromagnetic interference ; 

 

There are too much devices connected to the RS485 bus; 

And vice versa, the max transmission distance shall become longer. 

 

8.3

 

The Problem in Practical Use 

In practical usage, we usually adopt star type connection. The terminal resistance shall connect 

to the furthest two devices (Such as device 1# and device 15# in Figure 8-1. But this connection 

way does not conform to RS485 Bus standard. When the distances between devices are too 

long, the signal reflection occurs and anti-jamming decreases, thus the signal reliability becomes 

very low. You can see speed dome is not under control or speed dome is running automatically 

and cannot stop. 

 

 

Figure 8-1 

In this situation, we recommend RS485 distributor. This device can turn star type connection into 

the connection that conforms to RS485 bus industry standard, which can avoid the above 

mentioned problems and enhance communication reliability. See Figure 8-2. 

Baud Rate  Max Distance 
2400 BPS 

1800M 

4800 BPS 

1200M 

9600 BPS 

800M 

Содержание XP1080S20

Страница 1: ...XP1080S20 Quick Installation Speed Dome Installation Manual Version 1 0 ...

Страница 2: ...e 10 1 3 Initial Setup 12 1 4 Dial Switch Setup 12 1 4 1 Communication protocol and Baud rate 12 1 4 2 Address Setup 13 2 BRACKET DIMENSIONS 14 2 1 Wall mount bracket 14 2 2 Hanging mount bracket Multiple Lengths 14 2 3 Corner mount bracket 15 2 4 Pole mount bracket 15 3 WALL MOUNT BRACKET INSTALLATION 16 3 1 Component Installation 16 3 2 Installation 16 3 2 1 Installation Requirements 16 3 2 2 In...

Страница 3: ...ent Installation 20 5 2 Installation 20 5 2 1 Installation Requirements 20 5 2 2 Installation Steps 20 6 POLE MOUNT BRACKET INSTALLATION 22 6 1 Installation 22 6 1 1 Installation Requirements 22 7 APPENDIX Ⅰ THUNDER PROOF AND SURGE PROTECTION 24 8 APPENDIX Ⅱ ABOUT RS485 BUS 25 8 1 RS485 Bus Main Feature 25 8 2 RS485 Bus Transmission Distance 25 8 3 The Problem in Practical Use 25 8 4 RS485 Bus FAQ...

Страница 4: ...4 Welcome Thank you for purchasing our speed dome Please read the following safeguards and warnings carefully before you install or use the product ...

Страница 5: ...ll have the basic knowledge and operation technique for low voltage cable layout and low voltage electronic cable connection Please read the installation manual carefully and keep it well for future reference We are not liable for any problems caused by unauthorized modifications or attempted repair Lifting Appliance Requirement Please select the proper speed dome installation mode and use the lif...

Страница 6: ... The above mentioned objects in the device may result in fire short circuit or damage Please shut down the device and disconnect the power cable if there is water or liquid falling into the camera Please contact your local retailer ASAP Please pay attention to the camera Avoid the sea water or rain to erode the camera Handle carefully Do not allow this series product fall down to the ground Avoid ...

Страница 7: ...e speed dome and its corresponding installation component The safety factor shall be 4X About cable Please select the cable according to your transmission distance The minimum video coaxial cable requirement is 75 ohm Full cable with copper conductor 95 knitted copper shield International Model Max Distance Ft M RG59 U 750ft 229m RG6 U 1 000ft 305m RG11 U 1 500ft 457m Set dial switch button Set di...

Страница 8: ...the speed dome in wall mount bracket Open the transparent cover and take out the packing material EPE around the speed dome driver Please remove the protective paster from the driver and take off the camera lens cap See Figure 1 1 Figure 1 1 1 2 1 Address and Baud Rate Setup Now you can set the quick installation speed dome address and baud rate The speed dome interface is shown as below See Figur...

Страница 9: ...port and turn it into the screw thread of the wall mount bracket Use M4 stainless screws to secure firmly See Figure 1 4 Figure 1 4 Now you can begin the cable connection Connect the steel wire of the quick installation cover to the hook of the quick installation port Connect the reserved integration cable of the wall mount bracket to the corresponding power cable video output cable RS485 control ...

Страница 10: ...closure of the quick installation speed dome to the straight edge of the quick installation port and then push the speed dome to the bottom of the port slowly Use your hands to turn the three stainless screws of the quick installation port to the groove of the internal enclosure of the quick installation speed dome Turn the stainless screw of straight edge of the quick installation port to the Ф6 ...

Страница 11: ... sure The three stainless screws of the quick installation port are firmly secure The quick installation speed dome is fixed The speed dome is straight The steel wire connection is firm After your installation the interface is shown as in Figure 1 7 Figure 1 7 ...

Страница 12: ...note this series speed dome cans automatically recognize the DH SD PELCO D PELCO P Usually you do not need to set the protocol Figure 1 8 1 4 1 Communication protocol and Baud rate Please refer to the protocol sheets for detailed information Protocol Baud rate Parity 1 2 3 4 5 6 7 8 1 2 3 4 Communication Protocol OFF OFF OFF OFF DH SD Compatible with China industrial standard protocol ON OFF OFF O...

Страница 13: ...system 1 to 8 is valid bit The highest address bit is 255 You can refer to the following sheet for more information Address 1 2 3 4 5 6 7 8 1 OFF OFF OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF ...

Страница 14: ...t dimensions are shown as below See Figure 2 1 Figure 2 1 2 2 Hanging mount bracket Multiple Lengths The hanging mount bracket is shown as below See Figure 2 2 Figure 2 2 The bracket length setup values are 200mm 300mm 500mm You just need to replace the connection pole ...

Страница 15: ...15 2 3 Corner mount bracket The corner mount bracket is shown as below See Figure 2 3 Figure 2 3 2 4 Pole mount bracket The corner mount bracket is shown as below See Figure 2 4 Figure 2 4 ...

Страница 16: ...nts Before the installation please make sure The wall is thick enough to install the expansion bolt The wall can at least sustain the 4x weight of the speed dome 3 2 2 Installation Steps Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Use four hex bolts and flat washer ...

Страница 17: ...17 Install the speed dome in the bracket See Figure 3 3 Figure 3 3 Please refer to chapter 1 2 for detailed installation information ...

Страница 18: ...l the expansion bolt The wall can at least sustain the 4x weight of the speed dome 4 2 2 Installation Steps Loosen the M4 bolt in the flange side to separate the flange and steeve Pull the integration cable through the airproof slot of the bottom of the flange and then connect to the centre hole of the flange Please secure the flange in the ceiling See Figure 4 3 Please note if the speed dome is i...

Страница 19: ... the silica gel on the steeve connection surface to do the waterproof work See Figure 4 4 Figure 4 4 Please draw four holes position in the wall according to the hole of the bottom of the wall mount bracket Then you can dig four holes and insert the expansion bolts not provided Use four hex but and flat washer to fix the bracket in the expansion bolts See Figure 4 5 Figure 4 5 Please refer to chap...

Страница 20: ...ion bolt The wall can at least sustain the 4x weight of the speed dome 5 2 2 Installation Steps Please draw four holes position in the wall according to the holes of the corner installation accessories See Figure 5 2 Figure 5 2 Then you can dig four holes and insert the M8 expansion bolts Pull the power cable video control cable and the alarm cable through the centre hole of the bottom of the corn...

Страница 21: ...21 Figure 5 3 Please refer to chapter 1 2 for detailed installation information ...

Страница 22: ...h the installation dimension of the clamp Default factory clamp is six inches for the column of φ130 152mm It can work with the pole installation bracket You can adjust the diameter and the value clamp specification is φ59 82mm φ84 108mm φ103 127mm φ130 152mm φ155 178mm φ180 203mm φ194 216mm The clamp is shown as in Figure 6 2 Figure 6 2 For special dimensions please contact us for more informatio...

Страница 23: ...ower cable through the hanging bracket and then fix the hanging bracket to the wall Please pay attention to the waterproof between the bracket and the wall See Figure 6 4 Figure 6 4 Please refer to chapter 1 2 for detailed installation information Clamp and pole bracket connection Pole bracket and the pole connection ...

Страница 24: ...ne point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conform to ...

Страница 25: ...ax transmission distance shall become longer 8 3 The Problem in Practical Use In practical usage we usually adopt star type connection The terminal resistance shall connect to the furthest two devices Such as device 1 and device 15 in Figure 8 1 But this connection way does not conform to RS485 Bus standard When the distances between devices are too long the signal reflection occurs and anti jammi...

Страница 26: ...can control the speed dome but is not smooth RS485 Bus connection are not good One RS485 bus is off The distance between host and speed dome is too far Parallel connected too much speed domes Connect RS 485 Bus again Replace RS485 Bus Add terminal matching resistance Add RS485 distributor Note This manual is for reference only Slight difference may be found in the user interface All the designs an...

Отзывы: