![XVision XC960S30IRN Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/xvision/xc960s30irn/xc960s30irn_user-manual_891537010.webp)
XC960S30IRN
HD
960H
10
www.xvision.com
97+CALL
Begin image rollover function
98+CALL
Stop image rollover function
101+CALL
Defaulted setting
102+CALL
Switch manual operation speed (Fast/Medium/Slow)
103+CALL
Switch linear scanning speed (Fast/Medium/Slow)
107+CALL, 108+CALL
Calling 107 followed by 108 will restard the dome
109+CALL
Start communication for fault indication
110+CALL
Close communication for fault indication
4.2 Keyboard Operation
4.2.1 Preset Location Scan
There are a total of 4 preset routines and 32 preset locations can be set. To set the preset location;
1. Execute the command of setting a preset location.
2. Call the desired set option to the preset location.
3. Then, wait for the length of time you wish that preset point to stay in that position.
4. Call the next routine you want to set a preset location to.
5. Execute the command of setting a preset location and save the set.
4.2.2 Area Scanning
There are 2 ways of setting the area scanning.
1. Using special preset location order
Set the left boundary of region 1 by pressing the ‘44+CALL’ preset.
Set the right boundary of region 1 by pressing the ‘45+CALL’ preset.