10
i.
Disconnect power supply of the heat pump before any examination and repair.
The unit must
always be powered off before opening the access panel. Always cut
off the unit’s main power
whenever the access panel is open or removed.
ii.
In winter seasons, please drain water clear of the machine, disconnect power
Supply to
prevent any machine damage, and cover the machine body with plastic
cover to avoid dust.
If the unit is stopped for a long period of time or for winterizing,
the unit must be drained of all
its water. You will need to disconnect the IN and
OUT water connections. Then the unit must
be tilted or blown out with air until all
water is out.
iii.
Please clean this machine with household detergents or clean water, NEVER
gasoline,
thinners or any similar fuel. The area around the unit should be dry, clean
and well
ventilated. Clean the side heating exchanger regularly to maintain good
heat exchange and
conserve energy. Dirt can accumulate on the evaporator. You
can easily remove it by using
a non-pressured water spray without damaging the
small aluminum fins. The cleaning of the
plastic cabinet can be done with the help
of a brush and soap.
iv.
Check bolts, cables and connections regularly.