background image

 

www.XtremeAirUsa.com

                                                                    PAGE 

10

 

 

3.    FOR ALL ULTRA SERIES: TYPE 3: MECHANICAL BUTTON CONTROL   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.    FOR DL08 & DL09 Model: TYPE 4: ELECTRONIC BUTTON CONTROL   

 
 
 
 
 
 
 

 
 
 
 

 

 

 

OTHER THAN DL08-W48 

DL09-W48 

Body Design   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Non-Magnetic 1.0 mm Stainless Steel, Satin Finish   

Power Rating   

120V/60Hz (USA & Canada standard) 

120V/60Hz (USA & Canada standard) 

General Input Power   

158W (150W + 4x2W) 

308W (150W + 4x2W) 

Motor Input Power   

150 W each 

150 W each 

Ampere   

1.3 A 

2.6 A 

Levels Of Speed Control 

4 Levels 

4 Levels 

Maximum Airflow 

900CFM 

1600CFM 

Noise Level 

Approximately 1.5 – 6.0 sones or 33 – 54 dB 

Approximately 3.0 – 7.0 sones or 41 – 56 dB 

Number Of Motors   

Single Motor 

2 Motors 

Motor Type   

Single Chamber Ultra Quiet 

Single Chamber Ultra Quiet 

Fan Type   

Squirrel Cage blower 

2 Squirrel Cage blowers 

Filtration Type   

Heavy Duty Stainless Steel Baffle Filter 

Heavy Duty Stainless Steel Baffle Filter 

Illumination   

2/3/4 LED lights, 2W Maximum/each 

4 LED lights, 2W Maximum/each 

Venting Size   

Top 6 inches Round 

Top 8 inches Round 

Interference Protection   

Radio Frequency Interference Protected 

Radio Frequency Interference Protected 

Note 

Specification subject to change without notice. 

Specification subject to change without notice. 

 
 
 

1.    If the range hood or lights does not operate after installation: 

  Check if the range hood has been plugged in.    Make sure that all power has been turned back ON.   

 

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs.   

 

 

2.    The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly to the cabinet or wall. 

 

Check if the blower wheel is damaged.       

12. SPECIFICATION 

13. TROUBLESHOOTING 

A. Activating Blower Function: 

Press (0) once (flashing) 

Press your designed speed (1,2,3,4) 

B. Active delay power shut off / turn off power: 

While the blower (motor) is running, press (0) once to active 3 min power delay shut off 

Press (0) again to turn off blower and power. 

C. To turn the light ON/OFF & Dimmer 

While the light is off, press (5) once to turn on the light 

Press (5) again to turn dimmer down to lower setting 

Press (5) again to turn the light off. 

 

 

A. Activating Blower Function: 

Press your designed speed (1,2,3) 

B. Turn off power: 

While the blower (motor) is running, press button (0) to turn off the motors. 

C. To turn the light ON/OFF 

While the light is off, press button (4) once to turn on the light. 

Press button (4) again to turn the light off

 

 

A.Make sure the range hood is unplugged or turn OFF breaker.   
B.Pop out the light by pressing behind the light fixture. 
C.Install new light bulb. 
D.Put the light set back by pressing it in. 
E.Plug in and range hood to test for operation. 

 

Содержание Deluxe Series

Страница 1: ...ONS FOR RESIDENTIAL INDOOR USE ONLY Pro X Series PX01 W30 36 PX02 W30 36 PX03 W30 36 PX04 W30 36 42 PX04 W30 36 42 B PX06 W30 36 42 48 Ultra Series D02 W30 36 UL02 W30 36 UL03 W30 36 Deluxe Series DL0...

Страница 2: ...s intended for qualified installers service technicians or persons with a similar qualified background Installation and electrical wiring must be provided by qualified professionals and in accordance...

Страница 3: ...ll joints with aluminum tape Use caulking to seal exterior wall or roof openings around the cap The ventilation system must have a damper If the roof or wall cap has a damper you may opt out from usag...

Страница 4: ...2 2 2 2 2 W A S WALL ANCHOR SCREW 4 4 4 4 4 4 4 4 4 C S UPPER INNER CHIMNEY SCREW 4 ATTACHE D 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED 4 ATTACHED C G CAPONY GLASS 1...

Страница 5: ...www XtremeAirUsa com PAGE 5 8 HOOD DIMENSIONS INSTALLATION OVERVIEW PX08 W36 42 PX04 W30 36 42 PX06 W30 36 42 PX08 W48 PX02 W30 36 UL02 W30 36 PX03 W30 36 UL03 W30 36 PX01 W30 36...

Страница 6: ...Level the hood body by using horizontal level C Use hand screw driver to tighten those 2 mounting screws D Connect the exhaust on the hood to the ductwork above E Use aluminum tape to make all joints...

Страница 7: ...Operation Try a few test runs to ensure machine is running properly STEP 6A FOR PX01 MODEL ONLY INSTALL GLASS CANOPY A Loosen the four canopy screws and washers from the hood top B Carefully place th...

Страница 8: ...ion 1 While the range hood is on and the blower is running in normal mode touch Power Off Delay button to activate delay off timer 2 Adjust to desired period of delay of timer by touching or button qu...

Страница 9: ...l remain the same the next time it is turned on B ADJUSTING BLOWER SPEED Touch and hold down for increase Touch and hold down for decrease C TURNING OFF THE BLOWER Touch and hold down power sign 1 for...

Страница 10: ...tice 1 If the range hood or lights does not operate after installation Check if the range hood has been plugged in Make sure that all power has been turned back ON Swap out light assembly to working o...

Страница 11: ...ommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding SAFETY WARNING Never put your hand into area housing the fan whi...

Страница 12: ...www XtremeAirUsa com PAGE 12 16 LIMITED WARRANTY...

Отзывы: