INSTALLATION
9.
Clean the lid sealing ring and the edge of the filter box.
10.
Push one filter plate with the collar facing upwards, onto the lattice pipe and the cleaning rods.
11.
The filter sponges are pushed on from the casing lid, starting with a large blue filter sponge and always
alternating with a small yellow filter sponge. The cleaning rods lie in the two openings of the large chamber
of filter sponges.
12.
Put the filter plate with the collar facing downward. Fasten the cleaning rods flush to the filter plate using
two screws.
13.
Place the lid seal onto the upper edge of the filter box. To make an easy fit you can wet the seal ring.
14.
Place the tension ring onto the edge of the filter box. Place the tension ring onto the edge of the filter
box and lid, press down on the lid and click the fastening into place. Push safety latch in.
18.
Fasten all hoses with flat seals or flow vane to the corresponding connection by screwing the union nuts
on tightly. Start the pressure filter on again.
REPLACING THE UVC LAMP
The UVC Lamp must be replaced after 8,000 hours of operation in order
to ensure that the filter continues to operate with optimum effectiveness.
1.
Unscrew the eight screws of the filter cover and handle. Pull the lamp
from the lid of the filter.
2.
Pull the UVC lamp and replace it with a new one.
3.
Insert the filter UVC in the lid of the filter and screw the eight screws.
Start the pressure filter up again.
7
TROUBLESHOOTING