Xtreme Power 71015 Скачать руководство пользователя страница 6

INSTALLATION

POND SIZE / WITH OR WITHOUT FISH

The filter system with integrated UVC must be running permanently, 24 hours a day. The UVC lamp must be 

replaced after 8,000 hours of operation in order to ensure that the filter UVC continues to operate properly. 

The selection table allows for a maximum height difference of 1m between 

the surface of the water and the highest point of the filtering system. If the 

height difference is greater than 1m, you should use a corresponding pump 

with more power. For hoses that are longer than 4m, always use hoses that 

correspond to the upper value of the scale. 

PRESSURE LOSS DUE TO HEIGHT DIFFERENCE

In order to avoid pressure loss, cut the spiral stepped hose adapter at the 

relevant points for each hose. Avoid unnecessary corners and bends which 

contribute to further pressure loss. 

Choose a suitable location for the pressure filter. Install the filter so that it 

is safe from flooding. Secure your filter so that it won’t fall into the pond. Be 

sure to place it at least 2m from the edge of the pond. 

INSTALLING AND CONNECTING THE PRESSURE FILTER

Place the filter on a firm, level base. The filter can also be dug in up to the 

step on the filter box. Make sure there is unhindered access to the lid in 

order to be able to carry out work on the filter. 

Decide which hose diameter you need based on the selection table. Only 

operate the filter with pressure hoses that are approved for a pressure of 

0.2bar (the maximum pressure of the pump). It is recommended to warm 

the hose with hot water, pushing it onto the spiral stepped hose adapter and 

securing it with a hose clip. This makes the connection watertight. To avoid 

pressure loss, cut the spiral stepped hose adapter at the relevant point to 

fit each hose. 

CONNECTION AT THE WATER INLET

Push the union nut onto the black spiral stepped hose adapter. Push/twist the hose on and secure with a 

hose clip. Insert the flat seal into the union nut and screw tight onto the water inlet nozzle. We recommend 

diverting the clean water via a small watercourse, for example, instead of feeding it directly back into the 

pond. This enriches the water with additional oxygen. Connecting to a cleaning connection, you can have a 

drainage hose permanently connected to the cleaning connection. This allows you to drain the dirty water 

directly into the sewage system or onto a flower bed. 

5

Содержание 71015

Страница 1: ...PERATING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 71015 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...anual and have developed a thorough understanding of how it works DO NOT modify this product in any way Unauthorized modification may impair the function and or safety and could affect the life of the product There are specific applications for which the product was designed Keep children and bystanders away from the work area while operating the filter DO NOT allow children to handle the product ...

Страница 3: ...he appliance if it will not fit the outlet instead have a proper outlet installed by a qualified technician DO NOT use with pumps that exceed 4500 gallons per hour This could damage the filter DO NOT use pumps with flows less than 2500 gal hr A minimum of 2500 gallons per hour is necessary to perform the back flush operation NOTE All pressure filters restrict the flow from your pump Expect about a...

Страница 4: ...s powerful filter cleans out harmful algae and growth using a UV light purifier Transform dirty green pond water into a crystal clear oasis so your fish can live longer and happier for years to come Does not include pump No assembly required Includes inlet and outlet adapters Powerful filter for 2500 gallons with a normal fish load or 1500 gallons with a heavy fish load UV purifier reduces algae b...

Страница 5: ... VORTEX SYSTEM Suspended matter and bio sludge are precipitated by the centrifugal affect and gravity C MECHANICAL FILTER Dirt particles are trapped by the outer surface of the filter sponges before the water flows the entire height of the filter from the edge into the inner chamber of the filter D BIOLOGICAL CLARIFYING The yellow and blue filter sponges differ in size and density This creates zon...

Страница 6: ...RE FILTER Place the filter on a firm level base The filter can also be dug in up to the step on the filter box Make sure there is unhindered access to the lid in order to be able to carry out work on the filter Decide which hose diameter you need based on the selection table Only operate the filter with pressure hoses that are approved for a pressure of 0 2bar the maximum pressure of the pump It i...

Страница 7: ...tically 4 The filter should now be rinsed As soon as only clean water can be seen through the transparent spiral stepped hose adapter at the cleaning connection turn the function switch counter clockwise until it clicks into the Filter position 5 Screw the sealing cap with the inserted flat seal tightly onto the cleaning connection or the drainage hose that is connected to the cleaning connection ...

Страница 8: ...an wet the seal ring 14 Place the tension ring onto the edge of the filter box Place the tension ring onto the edge of the filter box and lid press down on the lid and click the fastening into place Push safety latch in 18 Fasten all hoses with flat seals or flow vane to the corresponding connection by screwing the union nuts on tightly Start the pressure filter on again REPLACING THE UVC LAMP The...

Страница 9: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...