background image

Connecting Power 

To Align the Photo Eye Safety System: 

1. 

When the Photo Eye System is properly connected and the 
power is connected, one of the Photo Eyes will emit a 
steady green light. This Photo Eye is the Emitter that     
generates the Invisible Light Beam. 

2. 

When properly aligned, the Sensor should emit a steady 
red light when it senses the invisible light beam from the 
Emitter. 

3. 

If the indication is unsteady, flashes or is dim, check for 
any obstructions and adjust the position until the Sensor 
gives a STEADY RED LIGHT. 

Note: The path of the invisible light beam MUST NOT be  

obstructed. No part of the garage door or any 

 

 

 

 

 

 

hardware should interfere with the beam or the Open-
er will not close the door.

 

Aligning the Photo Eye Safety System 

For Permanent Wiring ONLY

 

DO NOT OPERATE OPENER AT THIS TIME. 

To Connect Power

 

Plug the Opener into a grounded outlet ONLY. If there is no 
grounded outlet present, call a qualified electrician to replace the 
outlet.  

Permanent Wiring (If Required by Local Code)

 

1. 

Remove the enclosure by removing the 6 screws located 
on the sides and rear of the Opener. 

2. 

Cut the two wire connectors found inside and remove the 
power cord. 

3. 

Group neutral (white) wires from power source with 2 white 
(W) wires and 1 yellow (Y) wire inside the Opener.         
Connect them with a wire nut (not provided). 

4. 

Group line (black) wires from power source with black wire 
(B) inside the Opener. Connect them with a wire nut      
(not provided). 

5. 

Secure the ground (green or bare) wire from the power 
source with a grounding screw. 

6. Reinstall 

the 

enclosure. 

7. 

Turn on power supply.  If the wiring is properly connected, 
a “click” should be heard and the light will illuminate (if a 
bulb is installed). If there is no response from the Opener, 
check power source and wiring. 

WARNING 

To prevent SERIOUS INJURY or DEATH from electrocution or fire: 

- Power MUST be DISCONNECTED BEFORE proceeding with permanent wiring procedures. 
- Garage Door Opener installation and wiring MUST be in compliance with all local electrical and building 

codes. Make sure the Opener is ALWAYS grounded. 

- NEVER use an extension cord, 2-wire adapter or modify the power plug in any way to make it fit the outlet.

 

Ground screw (green)

 

Conduit with wire

 

Y

 

W

 

Neutral (W)

B

 

Wire nut

 

W

 

Line (B )

 

Ground (G)

 

Ordinary Power Connection

 

Invisible Light Beam

 

15 

WARNING 

To prevent SERIOUS INJURY or DEATH from a closing garage door: 

- The Photo Eye Safety System MUST be installed BEFORE connecting power. 

- The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener.

 

Содержание 425-1605

Страница 1: ...ty instructions carefully before installation The Opener WILL NOT CLOSE until the Photo Eye Safety System is properly installed and aligned REGULARLY CHECK and TEST the Opener according to the safety label to ENSURE SAFE OPERATION Retain this manual for future reference Serial __ __ __ __ __ __ __ Date Installed __ __ __ __ __ __ __ __ GDO Manual Revised 10 12 ...

Страница 2: ... Attaching Door Arms 10 Installing Light and Emergency Release Handle 11 Wiring Wiring Instructions 12 Connecting Photo Eye Safety System 13 Connecting Push Button 14 Connecting Power 15 Adjustment Aligning the Photo Eye Safety System 15 Travel Limit Adjustment 16 Force Adjustment 17 Final Adjustment and Testing 18 Operation Programming Hand held Transmitter 19 Operating the Opener 20 21 Maintenan...

Страница 3: ...e Safety Labels Chain Photo Eye Safety System Opener Unit Lamp Dome Sprocket Cover 2 Single Button Transmitter Push Button Header Bracket Door Bracket Trolley Door Arms Pulley Rail Header Segment Rail Middle Segments x3 INSTALLATION HARDWARE LOCATED IN HARDWARE BAG SHOWN IN ACTUAL SIZE Hanging Brackets Insulated Staples Securing wires x 2 Self Threading Screw 1 4 x 5 8 Door Bracket Trolley Shaft a...

Страница 4: ... tension Call a qualified garage door service technician if your door binds sticks or is unbalanced WARNING To prevent SERIOUS INJURY or DEATH Before beginning installation of the Opener please complete the following test to ensure that your door is balanced and in good working condition A poorly balanced door can cause serious injury and damage to the Opener Always have a qualified garage door se...

Страница 5: ...erting the 3 8 x 1 3 4 Clevis Pin through the top of the rail 4 Lock the Clevis Pin with a Hitch Pin Rotate the Pulley to ensure it spins smoothly Refer to Fig 3 to connect the Trolley Shaft to the Trolley Slide both the Trolley Shaft and Trolley towards each other A click will be heard when they are connected To Link Cable with Chain Refer to Fig 4 Place the chain carton beside the rail hold the ...

Страница 6: ...ned and not twisted Attach the Sprocket Cover to the Opener as shown in Fig 3 Notice During operation it is normal for the chain to appear loose when the door is closed If the chain returns to the position as shown below when the door is opened the chain is adjusted properly DO NOT re tighten the chain When performing maintenance always PULL the Emergency Release to DISCONNECT the door from Opener...

Страница 7: ...ing as shown in Fig 3 Center the Header Bracket on the vertical mark no more than 6 15cm from the header wall Mark and drill holes to fasten the Header Bracket securely to a structural support Mounting Header Bracket Fig 1 Ceiling Header Bracket Header Wall 2 5cm clearance Door Track Door Highest Point of Door Travel Support block on floor Door Spring UP OPENER MAX 6 15cm Highest Point of Door Tra...

Страница 8: ... to the reinforcement bracket If you have a door reinforcement bracket with this option skip this step and proceed with the next step Mounting Opener to Ceiling 1 Position the Door Bracket on the centerline of the door approximately 2 4 5 10cm below the top edge of the door as shown in Fig 2 2 Depending on the construction of your door install using one of the steps shown if Fig 3 below For steel ...

Страница 9: ...tural supports using 5 16 x1 2 Lag Screws provided 7 Secure the Opener to the Hanging Brackets and secure each side with a 5 16 x 1 Bolt and Flange Nut provided 8 Move the door manually to check clearance between highest point of travel of the door and rail If the door hits the rail raise the Header Bracket or adjust the mounting of Opener 9 Remove the ladder ONLY when the Opener is securely mount...

Страница 10: ... shown in Fig 1 1 CLOSE the door 2 Move the Emergency Release lever to the downward position to disconnect the Trolley from Trolley Shaft 3 Slide the Trolley so that it is about 8 20cm from the Pulley 4 Fasten the Curved Door Arm to the door Bracket with 5 16 x 1 Clevis Pin and lock it with a Hitch Pin 5 Fasten the Straight Door Arm to the Trolley with a 5 16 x 1 Clevis Pin and lock it with a Hitc...

Страница 11: ...lease Knob 1 Thread one end of the rope through the hole of the Emergency Release Knob and secure with an overhand knot 2 Thread the other end of the rope through the hole in the Trolley lever 3 Measure the rope length so that the knob is 6 feet 183cm above the floor and is clear from the top of your vehicle Secure with a overhand knot Fig 1 Fig 2 WARNING To prevent SERIOUS INJURY or DEATH from a ...

Страница 12: ...s MUST be connected with one white wire and one striped wire non polarized from the SAME accessory 5 Check for proper connection by gently pulling on the wire The wire should not come out of the terminal NO exposed part of the wire should be visible outside of the terminal 6 Use the insulated staples provided to secure the wires to the wall and or ceiling Be careful not to damage the wires while s...

Страница 13: ... Eye Safety System on page 15 Alternative Floor mounting 1 Place the Photo Eyes facing each other on each side of the garage door as shown in Fig 2 2 If attaching to concrete secure the photo eyes using concrete anchors and bolts not provided 3 If necessary align the Photo Eyes by loosening the wing nut This step may be further required in Aligning the Photo Eye Safety System on page 15 To Connect...

Страница 14: ...e with 1 screws If attaching to drywall or other hollow surface drill 3 16 holes and use the provided Drywall Anchors 3 Snap the Push Button onto the rear cover WARNING To prevent SERIOUS INJURY or DEATH from electrocution Power MUST NOT be connected until instructed To prevent SERIOUS INJURY or DEATH from using the Push Button and a closing door Install the Push Button within sight of the door at...

Страница 15: ... 3 Group neutral white wires from power source with 2 white W wires and 1 yellow Y wire inside the Opener Connect them with a wire nut not provided 4 Group line black wires from power source with black wire B inside the Opener Connect them with a wire nut not provided 5 Secure the ground green or bare wire from the power source with a grounding screw 6 Reinstall the enclosure 7 Turn on power suppl...

Страница 16: ...arance for your vehicle s and there is a minimum 2 5cm gap between Trolley and Stop Bolt 5 Perform Safety Reverse Test on page 18 If the door does not open past 5 feet 1 5m follow Force Adjustment on page 17 to adjust the Open Force Setting CLOSE DOWN Travel Limit 1 OPEN the garage door by using either the Transmitter or Push Button 2 Adjust the CLOSE Limit Screw 3 CLOSE the garage door and check ...

Страница 17: ...uring closing increase Close Force by 1 increment The Close Force is now properly adjusted 2 During the door close cycle the Opener will reverse if the force required to close the door is exceeded Setting Open Force 1 If the door completes a full open cycle without stopping decrease the amount of force by 1 level until the door stops during the opening Once the door stops during opening increase O...

Страница 18: ...e Safety reverse Test call a qualified technician for door adjustment Testing the Photo Eye Safety System 1 Open the door by using the Push Button or Transmitter 2 Make sure both Photo Eyes steadily emit the green and red indicator lights If not check alignment 3 Place an object under the door about 8 20cm high by 12 30cm wide the Opener carton can be used 4 The red indicator light on the sensor e...

Страница 19: ...e LEARN button for 5 seconds The courtesy light will flash 7 times indicating ALL Transmitters have been removed from memory Replacing Transmitter Battery When the battery of the hand held Transmitter is low the indicator light will become dim and or the range of the Transmitter will diminish To replace the battery remove the battery cover from the Transmitter as shown in Fig 4 Replace with a 23AE...

Страница 20: ...e Emergency Release Knob Photo Eye Safety System Invisible Light Beam Push Button Courtesy Light Activating the Opener WARNING To Prevent SERIOUS INJURY or DEATH READ AND FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THE OWNER S MANUAL AND LABELS Keep Transmitter and battery out of reach of children NEVER permit children to access the Push Button or remote Transmitters Operate the door ONLY when it is p...

Страница 21: ...onnect Operation Condition Courtesy Light Response Opener is initially plugged in Power restored Flashes twice Upon Opener activation Turns on for 3 1 2 minutes and turns off automatically LEARN button is pressed Turns on for 30 seconds Remote Transmitter Keyless Entry PIN code accepted Flashes twice The Photo Eye System is obstructed during door closing or door is obstructed during opening Flashe...

Страница 22: ... obstructed refer to page14 for proper alignment The Opener is working properly but the courtesy light does not turn on Replace light bulb A19 incandescent Max 100W The courtesy light does not turn off Defective Logic Board The Opener hums as the Trolley hits the Trolley Stop Bolt in open travel 1 Make sure the Trolley is towards the Trolley Stop Bolt 2 Disconnect the Trolley by using the Emergenc...

Страница 23: ...8 Chain Item Part No Name Description 1 24919 Header Bracket 2 24917 Door Bracket 3 24925 Hardware Bag Installation hardware shown on P 3 4 24921 Straight Door Arm 5 24923 Curved Door Arm 6 24924 Emergency Release Knob Rope 7 24941 Hanging Bracket Item Part No Name Description 1 24913 Photo Eye Safety System Emitter Sensor with Brackets 2 24915 Push button 3 24111 Hand held Transmitter 4 24939 12V...

Страница 24: ...ssembly 9 RPM wheel 10 Logic Board holder 11 Logic Board 13 Limit system assembly 14 24937 Opener cover 12 Limit system driving gear Green Screw Gear Close limit Contact Open limit Contact Center limit Contact Red Screw Orange Blue Green Limit System Assembly 1 2 3 4 5 6 7 8 9 11 10 12 13 14 Opener Assembly Parts Should be replaced by qualified technician only 24 ...

Страница 25: ... Products ATTN Warranty Dept 2301 Traffic Street NE Minneapolis MN 55413 ANY DISASSEMBLY MODIFICATION OR ABUSE OF THIS PRODUCT VOIDS THIS LIMITED WARRANTY DECKO DISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATED TO THE GARAGE DOOR OR GARAGE DOOR HARDWARE THIS...

Страница 26: ...NOTES ...

Страница 27: ...NOTES ...

Страница 28: ......

Отзывы: