Technical data
Please note that fundamentally, there are 2 different versions:
l
Standard version
l
High performance – version (H version)
The H version is distinguished by the following enhanced features:
l
The housing front pane is not made up of IR-transmissive sheeting, but a silicon-wafer pane which was
developed specifically for this application and is distinguished by its high transmissivity to IR radiation.
l
Camera-like look & feel
l
Because of its precision optics, its nominal ranges are greater than those of the standard versions
l
H-versions include an in-built heating mechanism
l
Because of this heating, they can also be used in harsh climatic conditions. The detectors can be used
despite temperature fluctuations because any air condensation that occurs, that could in turn damp
signals due to the very small water droplet formation in the front pane or on the mirror, is counteracted.
l
Additionally, there are two freely programmable zero potential relay outputs
The specifications below apply to all ADPRO PRO PIR detectors.
Technical Specifications
All ADPRO PRO E-detectors
Spectral response
8-14 μm, double filter
Detection speed
0.2 - 5.0 m/s
Sensitivity or range (with ADPRO
PRO-Tool-software)
20-140% (model specific)
Filter (window)
Standard version:
HDPE filter, IR-transmissive
High performance
H versions:
Silicon wafer (silica glass)
Vandalism detection, housing
Misalignment and aperture monitoring
(NC contact 30 V / 100 mA)
Alarm display
Internal LED
Alarm outputs
5 outputs per 75 mA max. at 60 V
DC
Communication
RS-485, 9.6 kBit/sec
Temperature compensation
Full compensation across the entire nominal operating temperature
range
Power supply
10.5 - 30V
DC
, 24V
AC
±15% (without heating)
Current consumption
18 mA @ 12V
DC
, 14 mA @ 24V
DC
Power consumption, heating
0.5 W / ~41 mA @ 12 V
DC
and -40°C (only H versions)
Operating temperature, nominal
Standard versions:
-20ºC to +60°C
High performance
H versions:
-40°C to +60°C
Cabling (terminal screws)
2 x 4-7 mm (0.16” - 0.27”)
Cable bushing
Cable exterior: Ø: 9 – 14 mm
(M16)
Dimensions (L x W x H) in mm
247 x 100 x 104
Installation
l
Pole installation
l
Wall installation
IP protection rating
IP65
Содержание ADPRO PRO E
Страница 2: ......
Страница 6: ...Installation Guide ADPRO PRO E by Xtralis 2 27386_05 This page is intentionally left blank ...
Страница 10: ...Installation Guide ADPRO PRO E by Xtralis 4 27386_05 This page is intentionally left blank ...
Страница 32: ...Installation Guide ADPRO PRO E by Xtralis 26 27386_05 This page is intentionally left blank ...
Страница 36: ...Installation Guide ADPRO PRO E by Xtralis 30 27386_05 This page is intentionally left blank ...
Страница 38: ...Installation Guide ADPRO PRO E by Xtralis 32 27386_05 This page is intentionally left blank ...
Страница 42: ...Installation Guide ADPRO PRO E by Xtralis 36 27386_05 ...
Страница 46: ...Installation Guide ADPRO PRO E by Xtralis 40 27386_05 This page is intentionally left blank ...
Страница 48: ...Installation Guide ADPRO PRO E by Xtralis 42 27386_05 Notes ...
Страница 49: ......