ERG700 Rower
21
Erratic Operation
Caution! Do not use this Rower for Heart Rate monitoring unless a steady, solid Actual
Heart Rate value is being displayed. High, wild, random numbers being displayed indicate a
problem.
Areas to look for interference which may cause erratic heart rate:
1. Microwave ovens, TV’s, small appliances, etc.
2. Fluorescent lights.
3. Some household security systems.
4. Perimeter fence for a pet.
5. Some people have problems with the transmitter picking up a signal from their skin. If
you have problems try wearing the transmitter upside down. Normally the transmitter will
be oriented so the Spirit Fitness logo is right side up.
6. The antenna that picks up your heart rate is very sensitive. If there is an outside noise
source, turning the whole machine 90 degrees may de-tune the interference.
7. Another Individual wearing a transmitter within 3’ of your machine’s console.
If you continue to experience problems contact your dealer.
GENERAL MAINTENANCE
1. Wipe down all areas in the sweat path with a damp cloth after each workout.
2. If a squeak, thump, clicking or rough feeling develops the main cause is most likely one of
three reasons:
I. The hardware was not sufficiently tightened during assembly. All bolts that were in-
stalled during assembly need to be tightened as much as possible. It may be neces-
sary to use a larger wrench than the one provided if you cannot tighten the bolts suf-
ficiently. I cannot stress this point enough; 90% of calls to the service department for
noise issues can be traced to loose hardware.
II. The crank arm nut needs to be retightened.
III. If squeaks or other noises persist, check that the unit is properly leveled. There are 2
leveling pads on the bottom of the rear stabilizer, use a 14mm wrench (or adjustable
wrench) to adjust the levelers.