background image

2.5.1 

. 1  U s e r  S e t u p 

User setup includes password setup, display setup, bidirectional talk setup, 

DND setup,restore default settings, a touch screen sound button plus touch 
screen clean button setup. 

1. Password setup: includes passwords for user, arm, disarm with default 

123456 and anti-attack password with default 654321. 

2. Display setup: includes brightness (1-9), screensaver waiting time (from 

30s to 1800s with every 30s as an interval). 

3. Ring setup: ring selection for incoming call (.pcm format), alarm ring 

selection (.pcmformat), volume (0-10). 

2 . 5 . 3  P r o d u c t  I n t r o d u c t i o n 

This section mainly introduces product function and problems may encounter 

during usage. 

2.6 

Unlock

 

Function

 

Under incoming call from door station, call with door station and VDP 

monitoring door station, press unlock button to remotely unlock door. 

2.7 

Arm

/

Disarm

 

Function

 

Under arm/disarm status, click arm button at the lower right corner of main 

menu, and then select 1 from the 4 modes available (away, in, sleep and user 
mode). The password box pops up, and you need to input password for arming. 
System will enter arming status after delay ends. If you select instant arming, 
system will enter arming right after sound stops. 

Under arm status, click disarm button at the lower right corner of main menu 

and password box pops up. You need to input password for disarming. If you 
input correct password, the system will disarm; if you input incorrect password, 
you will see a message saying “incorrect password, please try again”. 

4. Bidirectional talk setup: 

Door station ring duration (15s, 30s, 45s,60s,90s,120s, adjustable); 
VDP ring duration (15s, 30s, 45s,60s,90s,120s, adjustable); 
Door station call duration (15s, 30s, 45s, 60s, 90s, 120s, adjustable); 
VDP call duration (5 min, 10  min, 15  min, 30  min, 45  min, 60 min, adjustable); 
Monitoring duration (15s, 30s, 60s, 90s, 120s, 180s, 300s, adjustable); 

5. DND setup: select from 0 hour (0H), 1 hour (1H), 2 hours (2H), 4 hours (4H), 
8 hours (8H) and 24 hours (24H) to block out local ring. 
6. Restore default settings: restore all user settings to default. 
7. Touch screen sound button: may select to have sound or not when you 

touch screen. 

8. Touch screen clean button: after you turn on this option, the screen will 

be off in 45s which allow you to clean it up with a piece of dry cloth. 45s later, 
the screen will resume to normal status. You may exit anytime during the 45s 
by pressing unlock button. 

2.8 

Screen

 

Cali bration

 

Function

 

 

This product screen was calibrated before shipped out. If you cannot activate 

icons on screen when you touch it, please press arm, and the product 

will enter screen calibration interface. Following the cursor, click on the 5 cursors 
in sequence to complete screen calibration. Once you have done, system will   
say screen calibration succeeds. 

2.5.2 

. 2  P r o j e c t  S e t u p 

This setup includes device info, network terminal, restore default settings. 
1. Device info: includes room number, IP address, subnet mask, default 

gateway, MAC address,and version info. 

2. Network terminal: includes door station name, device type, door station 

ID (manufacture use only), door station IP address, network port number, 
working status. You may edit each item by clicking it (a numeric keyboard pops 
up). After you complete setup, click the OK button on numeric keyboard. 

3. Restore default settings: restore all project settings to default. 

9

 

 

 

 

Содержание PM-IP-701TMD

Страница 1: ...I nfo Unlock Pow er 1 2 Butto ns SOS Arm Call Monitor Unlock Figure 1 6 The buttons are illustrated in Figure 1 6 Their descriptions are shown in Chart 1 1 2 df PM IP 701TMD PM IP 702TMDd 2 wire indoor monitors User manual ...

Страница 2: ...end call by pressing call button again and VDP will return to standby interface Chart 1 1 2 2 2 Video Bidirectional Talk with Door Station When door station calls VDP VDP will ring and display video from door station You may press call button or answer icon to answer call and achieve bidirectional talk with the door station While VDP is displaying video from door station you may end call and video...

Страница 3: ...rmation of saved VDP info which allows direct operation to call add edit delete and delete all You may add by clicking blank or add button to add resident info You may edit resident info by selecting saved info and click edit button 2 3 Alarm Fun ction This product can be connected to up to 8 channels alarm with 1st channel as SOS button 2nd channel as gas alarm 3rd channel as smoke alarm while th...

Страница 4: ...s 45s 60s 90s 120s adjustable VDP ring duration 15s 30s 45s 60s 90s 120s adjustable Door station call duration 15s 30s 45s 60s 90s 120s adjustable VDP call duration 5 min 10 min 15 min 30 min 45 min 60 min adjustable Monitoring duration 15s 30s 60s 90s 120s 180s 300s adjustable 5 DND setup select from 0 hour 0H 1 hour 1H 2 hours 2H 4 hours 4H 8 hours 8H and 24 hours 24H to block out local ring 6 R...

Страница 5: ...bedded loudspeaker Bidirectional Talk Support bidirectional talk Display Screen Dimension 7 inch TFT full real color Operating Mode Input Mechanical button SOS arm call monitor unlock touch screen technology Alarm Alarm Input Support 8 channels alarm input Network Ethernet 10M 100Mbps self t Networking Protocol TCP IP Speci cations Power DC 10 15V or AV direct feed Power Consumption Standby 1 5W W...

Страница 6: ...be done by professional staff If there is any malfunction or failure please do not try to dismount or x it by yourself and please contact after sales department for assistance Please refer to Figure 5 1 as guide Chart 4 1 Figure 5 1 Device Installation Guide No Name Description 1 Alarm Interface 8 ch alarm please see tag for details 2 Communication Port May directly connect to network cable or via...

Отзывы: