background image

and can set contents such as protection zone type, NO/NC, alarm type, enter 

delay, exit delay. For 1st to 3rd channels therein, users can only set NO/NC 
type; for the remaining 5 channels, users can set all, while protection zone types 
consist of IR, gas, smoke, SOS, door sensor, theft alarm, tripwire.Enter and exit 
time can be set to 0s, 10s, 30s, 60s, 90s and 120s. Delay is available only with 
delay alarm setup. 

Users can make bypass and delete each protection zone, or make the selected 

protection zone invalid once or for longer period. 

“You are calling XX-X-XXXX” with beeps. When the residents answer, 
bidirectiona talk is enabled. You may end call and video by pressing call button 
or “end” icon. VDP will return to standby interface. 

2.2.4 

. 4  M o n i t o r i n g  F u n c t i o n 

Under standby interface, press monitor button or under “video bidirectional  

talk” status press “monitor”, and VDP will displays video from door station. Under 
monitoring interface, you may switch to next video from door station since the 
device support 8

-

ch  videos at the same time with 1 large window and 7 small 

windows. 

You may turn it off by pressing monitor button again and VDP will return to 

standby interface. 

2.2.5 

. 5   C a l l  R e c o r d   F u n c t i o n 

Under “video bidirectional talk” status click “call record”, you will see missed 

calls,received calls, and dialed calls, which include information of caller and 
time.You may go to different pages of records. You also may call, save, delete 
or delete all callers. 

2.2.6 

. 6  C o n t a c t s 

Under “video bidirectional talk” status click “call resident”, you may enter 

contacts by clicking contacts icon (on the right of call box). The interface includes 
information of saved VDP info which allows direct operation to call, add, edit, 
delete and delete all.You may add by clicking blank or add button to add resident 
info. You may edit resident info by selecting saved info and click edit button. 

2.3 

Alarm

 

Function

 

This product can be connected to up to 8 channels alarm with 1st channel as 

SOS button, 2nd channel as gas alarm, 3rd channel as smoke alarm while the 
remaining5 channels can be exibly set. 

Under sub-menu there is information of protection zone status, alarm records 

and modesetup. 

2 . 3 . 1  P r o t e c t i o n  Z o n e  S t a t u s  F u n c t i o n 

This device mainly displays information of protection zone type, current 

status,and delay time for the 8 protection zones. Users may enter setup interface 
of protection zone by clicking setup button (password required), 

2 . 3 . 2  A l a r m  R e c o r d i n g  F u n c t i o n 

 

Alarm recording mainly records information of the time alarm happens, 

protection zone NO., alarm processed or not. The alarm info will be updated to 
management platform synchronously. 

When alarm happens in any protection zone, there will be a 15s beep locally 

with alarm interface pops up. 

2 . 3 . 3  M o d e  S e t u p 

Alarm of this product consists of away mode, in mode, sleep mode, and user 

mode. You may set each mode to on/off separately for each protection zone. 
Default setup are as follows: 

Away mode: 1-8 channels all on; 

In mode: 1-3 channels on, others off; 
Sleep mode: 1-5 channels on, others off; 
User mode: all off. 

2.4 

Info

 

Search

 

Function

 

 

After VDP receives messages (announcement) sent from platform, light turns 

on.Under “info search” click “announcement”, you may view announcements 
ranked by title and time. If you select one announcement and click search, you 
may view details of the selected announcement. 

2.5 

System

 

Setup

 

Function

 

 

System setup function includes user setup, project setup, and product 

introduction. 

7

 

 

 

 

 

Содержание PM-IP-701TMD

Страница 1: ...I nfo Unlock Pow er 1 2 Butto ns SOS Arm Call Monitor Unlock Figure 1 6 The buttons are illustrated in Figure 1 6 Their descriptions are shown in Chart 1 1 2 df PM IP 701TMD PM IP 702TMDd 2 wire indoor monitors User manual ...

Страница 2: ...end call by pressing call button again and VDP will return to standby interface Chart 1 1 2 2 2 Video Bidirectional Talk with Door Station When door station calls VDP VDP will ring and display video from door station You may press call button or answer icon to answer call and achieve bidirectional talk with the door station While VDP is displaying video from door station you may end call and video...

Страница 3: ...rmation of saved VDP info which allows direct operation to call add edit delete and delete all You may add by clicking blank or add button to add resident info You may edit resident info by selecting saved info and click edit button 2 3 Alarm Fun ction This product can be connected to up to 8 channels alarm with 1st channel as SOS button 2nd channel as gas alarm 3rd channel as smoke alarm while th...

Страница 4: ...s 45s 60s 90s 120s adjustable VDP ring duration 15s 30s 45s 60s 90s 120s adjustable Door station call duration 15s 30s 45s 60s 90s 120s adjustable VDP call duration 5 min 10 min 15 min 30 min 45 min 60 min adjustable Monitoring duration 15s 30s 60s 90s 120s 180s 300s adjustable 5 DND setup select from 0 hour 0H 1 hour 1H 2 hours 2H 4 hours 4H 8 hours 8H and 24 hours 24H to block out local ring 6 R...

Страница 5: ...bedded loudspeaker Bidirectional Talk Support bidirectional talk Display Screen Dimension 7 inch TFT full real color Operating Mode Input Mechanical button SOS arm call monitor unlock touch screen technology Alarm Alarm Input Support 8 channels alarm input Network Ethernet 10M 100Mbps self t Networking Protocol TCP IP Speci cations Power DC 10 15V or AV direct feed Power Consumption Standby 1 5W W...

Страница 6: ...be done by professional staff If there is any malfunction or failure please do not try to dismount or x it by yourself and please contact after sales department for assistance Please refer to Figure 5 1 as guide Chart 4 1 Figure 5 1 Device Installation Guide No Name Description 1 Alarm Interface 8 ch alarm please see tag for details 2 Communication Port May directly connect to network cable or via...

Отзывы: