![XtendLan PEDOMEOIR48023SD Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/xtendlan/pedomeoir48023sd/pedomeoir48023sd_user-manual_3739180019.webp)
preset positions in memory at most.
Setup of tour group
a. In the keyboard initial state, enter number “140”(110) and press the “PREVIEW”
key to enter the tour setup.
b. After entering the setup, add preset position number to the tour. Enter the first
desired preset position number and press the “PREVIEW” key, and the first preset
position is successfully added. Then it goes to the second one. Enter the second
desired preset position number and press the “PREVIEW” key, and the second
preset position is successfully added. More preset position can be added in the same
way.
c. After all the required preset positions having been added in the tour, enter the
number “141”(111) on the keyboard and press the “PREVIEW” key to exit the tour
setup.
1. Start Running a Tour
In the keyboard initial state, enter number “142”(112) and press the “PREVIEW”
key to start running the preset tour.
Example: Setup the tour order to be 1
→2→5→3→4→6 (please setup preset
positions before tour setup)
1.
Preview preset position 140(110) to enter tour setup (Enter number
“140”(110) and press the “PREVIEW” key)
2.
Preview preset position 1 to setup the first tour position (Enter
number “1”and press the “PREVIEW” key)
3.
Preview preset position 2 to setup the second tour position (Enter
number “2”and press the “PREVIEW” key)
4.
Preview preset position 5 to setup the third tour position (Enter
number “5”and press the “PREVIEW” key)
5.
Preview preset position 3 to setup the fourth tour position (Enter
number “3”and press the “PREVIEW” key)
6.
Preview preset position 4 to setup the fifth tour position (Enter
number “4”and press the “PREVIEW” key)
7.
Preview preset position 6 to setup the sixth tour position (Enter
number “6”and press the “PREVIEW” key)
8.
Preview preset position 141(111) to exit tour setup (Enter number
“141”(111) and press the “PREVIEW” key)
9. Preview preset position 142(112) to start running the tour, and the
constant speed ball runs the tour and begins to scan in the order of
1
→2→5→3→4→6.
If other devices are used to control the constant speed ball, due to the
protocol limitation, some special functions of the constant speed ball may be
not operational.
(Enter number “142” (112) and press the “PREVIEW” key)
3-5. Setup of Left/right Limiting Positions
The default rotating angle of the set is 360°. The user can reset running angle
according to the spot requirements. Left/right limiting positions of the dome can be