Parameter Function
Event
Type
There are three types: Motion detection/video loss/Camera Masking.
Channel
Select channel name from the dropdown list.
Enable
You need to draw a circle to enable motion detection function.
Sensitivity
There are six levels. The sixth level has the highest sensitivity.
Region
#
There are six levels. The sixth level has the highest sensitivity.
#
Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown as in Figure
7-43. There are PAL 22X18/NTSC 22X15 zones. Right click mouse
you can go to full-screen display mode. Do remember clicking OK
button to save your motion detection zone setup.
Period
#
Motion detection function becomes activated in the specified
periods.
#
There are six periods in one day. Please draw a circle to enable
corresponding period.
#
Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.
#
Click OK button, system goes back to motion detection interface;
please click save button to exit.
Anti-dither System only memorizes one event during the anti-dither period. The
value ranges from 3s to 600s.
Normal
out
Alarm
latch
Show
message
#
There is 2-channel alarm output.
#
Corresponding to motion detection alarm output port(multiple
choices)
#
Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.
System can delay the alarm output for specified time after alarm ende
The value ranges from 1s to 300s.
System pops up the alarm messages in the monitor interface.
Buzzer
Once you check the box here, the buzzer beeps when an alarm
occurred.
Alarm
upload
Record
channel
Record
latch
System can upload the alarm signal to the centre (Including alarm
centre.
System auto activates motion detection channel (multiple choices) to
record once alarm occurs (working with motion detection function).
Please note you need to go to Chapter 4.4 Schedule to set motion
detection record period and go to chapter 4.2 Manual Record to set
current period as auto record.
System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.
If you enabled this function, System can send out email to alert you
Содержание HVR-1608PK
Страница 1: ...HVR 1608PK HVR H408PKC Hybrid Standalone DVR User s Manual...
Страница 29: ...20 Please refer to the following figure for detailed information See Figure 2 5 General Series...
Страница 30: ...21 HVR H408PKC Series HVR 1608PK Series Figure 2 5...
Страница 41: ...32 General Series HVR H408PKC Series 3 7 2 Audio Output HVR 1608PK Series Figure 3 3...
Страница 43: ...34 HVR 1608PK Series Figure 3 4 3 8 Alarm Input and Output Connection General Series...
Страница 49: ...40 HVR H408PKC Series HVR 1608PK Series Figure 3 9...
Страница 65: ...Figure 4 24 56 Figure 4 21 Figure 4 22 Figure 4 23...
Страница 113: ...104 Figure 5 58...
Страница 115: ...106 direction arrows in DVR...
Страница 177: ...167 448K 196M 512K 225M 640K 281M 768K 337M 896K 393M 1024K 450M 1280K 562M 1536K 675M 1792K 787M 2048K 900M...
Страница 192: ...182...