background image

64

Figure 5-1

5.3 Setting

In main menu, highlight setting icon and double click mouse. System setting interface is shown

as below. See Figure 5-2.

5.3.1 General

Figure 5-2

General setting includes the following items. See Figure 5-3.

System time: Here is for you to set system time

Date format: There are three types: YYYYY-MM-DD: MM-DD-YYYYY or DD-MM-YYYY.

Date separator: There are three denotations to separate date: dot, beeline and solidus.

DST: Here you can set DST time and date. Please enable DST function and then click set

button. You can see an interface is shown as in Figure 5-4. Here you can set start time and

end time by setting corresponding week setup. In Figure 5-4, enable date button, you can

see an interface is shown as in Figure 5-5. Here you can set start time and end time by

setting corresponding date setup.

Time format: There are two types: 24-hour mode or 12-hour mode.

Language: System supports various languages: Chinese (simplified), Chinese (Traditional),

English, Italian, Japanese, French, Spanish (All languages listed here are optional. Slight

difference maybe found in various series.)

HDD full: Here is for you to select working mode when hard disk is full. There are two options:

stop recording or rewrite. If current working HDD is overwritten or the current HDD is full

Содержание DVR-x70PJ

Страница 1: ...1 DVR x70PJ 2U Series Standalone DVR User s Manual...

Страница 2: ...eries 15 1 3 3 8 HDDs Extra stream QCIF Series 18 2 OVERVIEW AND CONTROLS 22 2 1 Front Panel 22 2 2 Rear Panel 24 2 3 Connection Sample 24 2 4 Remote Control 25 2 5 Mouse Control 26 2 6 Virtual Keyboa...

Страница 3: ...put Bidirectional Audio 32 3 7 1 Audio Input 32 3 7 2 Audio Output 33 3 8 Alarm Input and Output Connection 34 3 8 1 Alarm Input and Output Details 34 3 8 2 Alarm Input Port 35 3 8 3 Alarm Output Port...

Страница 4: ...o Loss 52 4 5 4 Camera Masking 52 4 6 Alarm Setup and Alarm Activation 53 4 6 1 Go to alarm setup interface 53 4 6 2 Alarm setup 53 4 7 Backup 55 4 7 1 Detect Device 55 4 7 1 Backup 56 4 8 PTZ Control...

Страница 5: ...3 5 Network 68 5 3 6 Alarm 75 5 3 7 Detect 75 5 3 8 Pan Tilt Zoom 75 5 3 9 Display 76 5 3 10 Default 78 5 4 Search 78 5 5 Advanced 78 5 5 1 HDD Management 79 5 5 2 Abnormity 80 5 5 3 Alarm Output 80 5...

Страница 6: ...rol 89 6 2 5 Pattern Setup 89 6 2 6 Activate Pattern Function 90 6 2 7 Border Setup 90 6 2 8 Activate Border Function 90 6 2 9 Flip 90 7 WEB CLIENT OPERATION 92 7 1 Network Connection 92 7 2 Login 92...

Страница 7: ...SIONAL SURVEILLANCE SYSTEM 133 9 FAQ 134 APPENDIX A HDD CAPACITY CALCULATION 139 APPENDIX B COMPATIBLE USB DRIVE LIST 140 APPENDIX C COMPATIBLE CD DVD BURNER LIST 141 APPENDIX D COMPATIBLE SATA HDD LI...

Страница 8: ...to be a reference tool for the installation and operation of your system Here you can find information about this series DVR features and functions as well as a detailed menu tree Before installation...

Страница 9: ...apply power to the DVR before completing installation Do not place objects on the DVR 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers...

Страница 10: ...on transportation intelligent resident zone factory warehouse resources and water conservancy 1 2 Features This series product has the following features Real time monitor It has analog output port VG...

Страница 11: ...up function Slight function differences may be found due to different series 1 3 Specification 1 3 1 4 HDDs Series Parameter 4 ch with audio 4 ch without audio 8 ch with audio 8 ch without audio 16 ch...

Страница 12: ...information and privacy mask zone TV Adjust Adjust TV output zone suitable to anamorphic video Channel Lock Cover secret channel with black screen though system is encoding normally Screen lock functi...

Страница 13: ...n full screen when playback Record and playback Partial Enlargemen t When in one window full screen playback mode you can select any zone to activate partial enlargement function HDD backup Support pe...

Страница 14: ...ount alarm input and output amount system version and release date System Information On line user Display current on line user Multi lever user management various management modes Integrated manageme...

Страница 15: ...deo input NTSC PAL BNC 1 0VP P 75 8 CH composite video input NTSC PAL BNC 1 0VP P 75 16 CH composite video input NTSC PAL BNC 1 0VP P 75 Video Output 1 ch PAL NTSC BNC 1 0VP P 75 composite video signa...

Страница 16: ...on detection recording schedule recording Recording Length 1 to 120 minutes single record duration Default setup is 60 minutes Playback Repeat Way When hard disk is full system can overwrite previous...

Страница 17: ...You can set normal open or normal close type to select the alarm type Alarm Output 6 channel relay output including one controllable DC 12V output port Motion Detection and Alarm Alarm Relay 30VDC 2A...

Страница 18: ...NUX System Resources Multiplex operations Multiple channel record multiple channel playback and network operation simultaneously Interface User friendly graphical user interface Input Devices Front pa...

Страница 19: ...ing normally Screen lock function to prevent unauthorized user seeing secret video Channel Information Channel name recording status screen lock status video loss status and motion detection status ar...

Страница 20: ...via client Support network PTZ lens control File download backup and playback Multiple devices share information via corresponding software such as professional surveillance software PSS Duplex trans...

Страница 21: ...imit to the user or group amount Password modification Administrator can modify other user s password User Management Password Authenticati on Account lock strategy Five times login failure in thirty...

Страница 22: ...t to input a number more than 10 please click this button and then input In textbox click this button to switch between numeral English Small Capitalized donation and etc In preview window press it fo...

Страница 23: ...Various fast speeds and normal playback Play previous In playback mode playback the previous video Reverse Pau se In normal playback or pause mode click this button to reverse playback In reverse pla...

Страница 24: ...ail information 1 Power button 2 Power input port 3 Fan 4 Loop video output 5 1st to 4th channel audio input 6 Video input 7 DB25 port 5th to 16th channel audio input port 8 Audio output 9 Bidirection...

Страница 25: ...25 Figure 2 3 2 4 Remote Control The remote control interface is shown as in Figure 2 4 Please note remote control is not our standard accessory and it is not included in the accessory bag Figure 2 4...

Страница 26: ...arious forward speeds and normal speed playback 10 Previous Please refer to the previous in the front panel 11 Backward Various backward speeds and normal speed playback 12 Stop Please refer to the st...

Страница 27: ...t to playback the video Double left click mouse In multiple window mode double left click one channel to view in full window Double left click current video again to go back to previous multiple windo...

Страница 28: ...e text column the text is shown as blue input button pops up on the right Click that button to switch between numeral input and English input capitalized and small Use or to shift between small charac...

Страница 29: ...luded in the accessory bag 3 2 About Front Panel and Real Panel The model label in the front panel is very important please check according to your purchase order The label in the rear panel is very i...

Страница 30: ...ATA HDDs Please use HDD of 7200rpm or higher It has no requirement for HDD capacity You can refer to the appendix for recommended HDD brand Please follow the instructions below to install hard disk 1...

Страница 31: ...mply with your national standards The input video signal shall have high SNR low distortion low interference natural color and suitable lightness Guarantee the stability and reliability of the camera...

Страница 32: ...o defer aging do not allow the pc monitor to run for a long time Regular demagnetization will keep device maintain proper status Keep it away from strong electromagnetic interference devices Using TV...

Страница 33: ...dio output signal parameter is usually over 200mv 1K BNC It can directly connect to low impedance earphone active sound box or amplifier drive audio output device If the sound box and the pick up cann...

Страница 34: ...he connection between the alarm output port and the load 3 How to connect PTZ decoder a Ensure the decoder has the same grounding with DVR otherwise you may not control the PTZ Shielded twisted wire i...

Страница 35: ...re used to control devices such as PTZ Please parallel connect 120T between A B cables if there are too many PTZ decoders T 3 8 2 Alarm Input Port Please refer to the following sheet for more informat...

Страница 36: ...ard through RS232 With POS system the DVR can communicate through RS232 and network For the POS system the DVR can integrate the text content and even search the record through the info The series DVR...

Страница 37: ...pins in the connector on the camera 3 Please follow the instructions to configure a camera to enable each PTZ device on the DVR Figure 3 8 485 Port 3 11 Other Interfaces There are still other interfac...

Страница 38: ...888888 administrator local only Username 666666 Passwords 666666 Lower authority user who can only monitor playback backup and etc Username default Password default hidden user You can use USB mouse...

Страница 39: ...ss power button on the front panel for at least 3 seconds system will stop all operations Then you can click the power button in the rear panel to turn off the DVR 4 1 4 Auto Resume after Power Failur...

Страница 40: ...the HDD has been properly installed 4 2 2 1 Manual record menu There are two ways for you to go to manual record menu Right click mouse or in the main menu Advanced Manual Record In live viewing mode...

Страница 41: ...Setting Schedule The corresponding indication light in front panel will turn on Figure 4 7 All channel manual record Please highlight ALL after Manual See Figure 4 8 When system is in manual recordin...

Страница 42: ...re are three file types R Regular recording file A External alarm recording file M Motion detection recording file Playback control bar Select playback mode here 4 ch or All channel Set search setup h...

Страница 43: ...switch to the corresponding channel video of the same time 4 3 2 5 Digital zoom When the system is in full screen playback mode drag your mouse in the screen to select a section and then left click m...

Страница 44: ...I frame playback 4 3 2 9 Backward playback and frame by frame playback Button Illustration Remarks Backward play in playback interface In normal playback mode left click backward play button system b...

Страница 45: ...undancy backup function It allows you backup recorded file in two disks You can highlight Redundancy button to activate this function Please note before enable this function please set at least one HD...

Страница 46: ...ull Please note only read write disk or read only disk can backup file and support file search function so you need to set at least one read write disk otherwise you can not record video Note About re...

Страница 47: ...ion snapshot function After you enabled this function system can snapshot when the corresponding alarm occurred In Encode interface click snapshot button to input snapshot mode size quality and freque...

Страница 48: ...on Please enable FTP function and then click save button See Figure 4 16 Please boot up corresponding FTP server Please enable schedule snapshot Chapter 4 4 2 1 or activation snapshot Chapter 4 4 2 2...

Страница 49: ...here to view image content Select search engine here You can see result here Double click file name you can view the image content Figure 4 18 There are max 100 files in one page Click here to view mo...

Страница 50: ...tem can pop up a message to alarm you in the local host screen if you enabled this function Alarm upload System can upload the alarm signal to the network including alarm centre if you enabled current...

Страница 51: ...51 Figure 4 19 Figure 4 20 Figure 4 21...

Страница 52: ...Figure 4 24 This function allows you to be informed when video loss phenomenon occurred You can enable alarm output channel and then enable show message function Tips You can enable preset activation...

Страница 53: ...etup interface See Figure 4 26 4 6 2 Alarm setup Alarm interface is shown as below See Figure 4 26 Alarm in Here is for you to select channel number Event type There are two types One is local input a...

Страница 54: ...u to set proper delay duration Value ranges from 10 to 300 seconds System automatically delays specified seconds in turning off alarm and activated output after external alarm cancelled Tour Here you...

Страница 55: ...to Chapter 7 Web Client Operation for network download backup operation 4 7 1 Detect Device Click backup button you can see an interface is shown as in Figure 4 30 Here is for you to view devices inf...

Страница 56: ...files with a before channel name You can use Fn or cancel button to delete after file serial number Click backup button you can backup selected files There is a process bar for you reference When the...

Страница 57: ...ollow the procedures below to go on cable connection Connect the dome RS485 port to DVR 485 port Connect dome video output cable to DVR video input port Connect power adapter to the dome 4 8 2 PTZ Set...

Страница 58: ...tton in the front panel or click Fn key in the remote control The interface is shown as in Figure 4 34 Figure 4 34 Click Pan Tilt Zoom the interface is shown as below See Figure 4 35 Here you can set...

Страница 59: ...to adjust section size The dragged zone supports 4X to 16X speeds It can realize PTZ automatically The smaller zone you dragged the higher the speed Here is a sheet for you reference Figure 4 37 Name...

Страница 60: ...e 4 39 4 9 1Preset Setup In Figure 4 35 use eight direction arrows to adjust camera to the proper position In Figure 4 38 click preset button and input preset number The interface is shown as in Figur...

Страница 61: ...ris Go back to Figure 4 42 and click end button You can memorize all these operations as pattern 1 4 9 6 Activate Pattern Function Figure 4 42 In Figure 4 39 input mode value in the No blank and click...

Страница 62: ...op button Click stop button to terminate scan operation 4 10 Flip In Figure 4 39 click page switch button you can see an interface is shown as below See Figure 44 Here you can set auxiliary function T...

Страница 63: ...larm Detect Pan Tilt Zoom Display Default Search Advanced Shutdown HDD Management Alarm Output Abnormity Manual Record Account Auto Maintain TV Adjust Video Matrix 5 2 Main Menu After you logged in th...

Страница 64: ...e an interface is shown as in Figure 5 4 Here you can set start time and end time by setting corresponding week setup In Figure 5 4 enable date button you can see an interface is shown as in Figure 5...

Страница 65: ...o control several DVRs you can give a name to each DVR for your management Video standard There are two formats NTSC and PAL Auto logout Here is for you to set auto logout interval once login user rem...

Страница 66: ...annels the second channel to the eighth channel resolution shall be D1 CIF QCIF Right now in D1 resolution the max frame rate is 6f s Bit rate type System supports two types CBR and VBR In VBR mode yo...

Страница 67: ...rade program Keyboard is for you to use special keyboard to control current device Baud rate You can select proper baud rate Data bit You can select proper data bit The value ranges from 5 to 8 Stop b...

Страница 68: ...n Besides when PPPoE is operating you can not modify IP Subnet mask Gateway TCP port Default value is 37777 UDP port Default value is 37778 HTTP port Default value is 80 Max connection system support...

Страница 69: ...in the following list The list supports max 64 IP addresses Please note after you enabled this function only the IP listed below can access current DVR If you disable this function all IP addresses ca...

Страница 70: ...P 235 8 8 36 Multiple cast PORT 3666 After you logged in the Web the Web can automatically get multiple cast address and add it to the multiple cast groups You can enable real time monitor function to...

Страница 71: ...Eastern Time E T GMT 5 Atlantic Time GMT 4 Brazil GMT 3 Middle Atlantic Time GMT 2 5 3 5 6 DDNS Setup Figure 5 14 DDNS setup interface is shown as in Figure 5 15 You need a PC of fixed IP in the inter...

Страница 72: ...There are two modes Manual setup and auto setup Manual Setup You can double click DNS to set DNS address manually See Figure 5 16 Please input preferred DNS server IP and alternative DNS server IP Fi...

Страница 73: ...l Ser U FTP SERVER first From start program Serv U FTP Server Serv U Administator Now you can set user password and FTP folder Please note you need to grant write right to FTP upload user See Figure 5...

Страница 74: ...n for you to login the FTP File length is upload file length When setup is larger than the actual file length system will upload the whole file When setup here is smaller than the actual file length s...

Страница 75: ...r overload Figure 5 21 5 3 6 Alarm Please refer to chapter 4 6 Alarm Setup and Activation 5 3 7 Detect Please refer to chapter 4 5 Detect 5 3 8 Pan Tilt Zoom The pan tilt zoom setup includes the follo...

Страница 76: ...lay information System displays some information in the screen for your reference Resolution There are four options 1280 1024 default 1280 720 1024 768 800 600 Display mode you can select from the dro...

Страница 77: ...y You need to refresh web or client end to get the latest channel name System max support 25 digital character Figure 5 24 In tour mode you can see the following interface On the right corner right cl...

Страница 78: ...ease click save button system goes back to the previous menu Warning System menu color language time display mode video format IP address user account will not maintain previous setup after default op...

Страница 79: ...data in the HDD Please note system needs to reboot to get all the modification activated Important The read write HDD is to storage recorded file the snapshot HDD is to save the image You can search t...

Страница 80: ...e The value ranges from 10s 300s System automatically delays specified seconds in turning off alarm and activated output after external alarm cancelled Show message system can pop up the message in th...

Страница 81: ...there are two levels admin and user The user name and group name can consist of eight bytes One name can only be used once There are four default users admin 888888 666666 and hidden user default Exc...

Страница 82: ...ct proper setup from dropdown list After all the setups please click save button system goes back to the previous menu Figure 5 33 5 5 7 TV Adjust Here is for you to adjust TV output setup See Figure...

Страница 83: ...36 5 6 1 HDD Information Here is to list hard disk type total space free space video start time and status See Figure 5 37 means current HDD is normal X means there is error means there is no HDD If...

Страница 84: ...r go to HDD Management Chapter 5 5 1 to format HDD and then reboot the DVR Figure 5 37 Tips Please click Fn button or left click mouse to view HDD record time and HDD type and time 5 6 2 BPS Here is f...

Страница 85: ...n files 5 6 4 Version Figure 5 39 Here is for you to view some version information See Figure 5 40 Channel Alarm in Alarm out System version Build Date 5 6 5 Online Users Figure 5 40 Here is for you m...

Страница 86: ...u to select See Figure 5 42 Logout menu user log out menu You need to input password when you login the next time Restart application reboot DVR Shutdown system shuts down and turns off power Restart...

Страница 87: ...1 Figure 6 1 Click Pan Tilt Zoom the interface is shown as in Figure 6 2 Here you can set the following items Zoom Focus Iris Please click icon and to adjust zoom focus and Iris Figure 6 2 In Figure 6...

Страница 88: ...for you reference Figure 6 4 Name Function key function Shortcut key Function key function Shortcut key Zoom Near Far Focus Near Far Iris close Open 6 2 Preset Patrol Pattern Border Function In Figure...

Страница 89: ...gure 6 7 In Figure 6 6 please input preset number in the No blank and click preset button 6 2 3 Patrol Setup In Figure 6 5 click patrol button The interface is shown as in Figure 6 8 Input preset numb...

Страница 90: ...and then please go to Figure 6 10 and click left limit button Repeat the above procedures to set right limit 6 2 8 Activate Border Function Figure 6 10 In Figure 6 6 click auto scan button the system...

Страница 91: ...91 Figure 6 11...

Страница 92: ...the new version can overwrite the previous one If you want to un install the web control please run uninstall webrec2 0 bat Or you can go to C Program Files webrec to remove single folder Please note...

Страница 93: ...t your user name and password Default factory name is admin and password is admin Note For security reasons please modify your password after you first login Figure 7 3 After you logged in you can see...

Страница 94: ...ction 5 Here you can view window switch button You can also select video priority between fluency or real time System monitor window switch supports full screen 1 window 4 window 6 window 8 window 9 w...

Страница 95: ...m restores original status 2 Change show mode resize or switch to full screen mode 3 Local record When you click local record button the system begins recording and this button becomes highlighted You...

Страница 96: ...rt During the bidirectional talk process system will not encode the audio data from the 1 channel Local Play The Web can playback the saved Extension name is dav files in the PC end Click local play b...

Страница 97: ...ent positioning key system goes back to the single screen mode Drag the mouse in the screen to adjust section size It can realize PTZ automatically 7 2 2 2 Speed System supports eight level speed You...

Страница 98: ...to Figure 7 11 to implement camera operation Then you can click stop record button Now you have set one pattern 7 2 2 6 Preset In Figure 7 12 move the camera to your desired location and then input pr...

Страница 99: ...nd saturation Current channel border becomes green Or you can click default button to use system default setup Figure 7 14 7 2 4 Picture Path and Record Path Click more button in Figure 7 14 you can s...

Страница 100: ...following dialogue box See Figure 7 18 Please click OK to reboot Figure 7 18 If there is local use logged in the system menu or the Web logged in user has no right to reboot the device system pops up...

Страница 101: ...DD information Figure 7 19 Here you can view local storage status and network status including free capacity and total capacity See Figure 7 20 7 3 1 3 Log Figure 7 20 Here you can view system log See...

Страница 102: ...nagement alarm event record operation user management log clear and file operation Search You can select log type from the drop down list and then click search button to view the list Clear You can cl...

Страница 103: ...03 7 3 2 1 General Setup Here you can set system time record length video format and etc See Figure 7 23 Figure 7 23 Figure 7 24 Figure 7 25 Please refer to the following sheet for detailed informatio...

Страница 104: ...ds to reboot to get the modification activated HDD Full There are two options stop recording or overwrite the previous files when HDD is full When current working HDD is overwriting or it is full now...

Страница 105: ...otion stream and alarm stream You can select different encode frame rates form different recorded events System supports active control frame function ACF It allows you to record in different frame ra...

Страница 106: ...D1 and the frame rate is or less than 6f then the rest seven channels the second channel to the eights channel resolution shall be D1 CIF QCIF Right now in D1 resolution the max frame rate is 6f s Bit...

Страница 107: ...osition Copy It is a shortcut menu button You can copy current channel setup to one or more channels The interface is shown as in Figure 7 28 Save You can click save button after you complete setup fo...

Страница 108: ...sheet for detailed information Parameter Function Channel Please select a channel first Pre record Please input pre record value here System can record the three to five seconds video before activatin...

Страница 109: ...o save current time period setup Copy It is a shortcut menu button You can copy current channel setup to one or more all channels The interface is shown as in Figure 7 28 Save You can click save butto...

Страница 110: ...ven System default setup is Function Console Data bit 8 Stop bit 1 Baud bit 115200 Parity None 7 3 2 5 Network Network interface is shown as in Figure 7 32 Figure 7 32 Please refer to the following sh...

Страница 111: ...setup and then reboot the device to get the setup activated Device connects to the internet via PPPoE after reboot You can get the IP address in the WAN from the IP address column Please note if you...

Страница 112: ...sheet for detailed information Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function The private DDNS protocol means you use your self define...

Страница 113: ...file length you upload to the FTP When setup is larger than the actual file length system will upload the whole file When setup here is smaller than the actual file length system only uploads the set...

Страница 114: ...efault value is 10 minutes Figure 7 36 You can refer to the following sheet for time zone information City Region Name Time Zone London GMT 0 Berlin GMT 1 Cairo GMT 2 Moscow GMT 3 New Deli GMT 5 Bangk...

Страница 115: ...115 Figure 7 37 7 3 2 6 Alarm Alarm setup interface is shown as in Figure 7 38 Please make sure you have connected the corresponding alarm output device such as the light buzzer and etc Figure 7 38...

Страница 116: ...iod The value ranges from 0 to 15s Normal Out Enable alarm activation function You need to select alarm output port so that system can activate corresponding alarm device when alarm occurred Alarm Lat...

Страница 117: ...hannels Save You can click save button after you complete setup for one channel or you can complete the whole setups and then click save button Refresh Click this button to get device latest configura...

Страница 118: ...tion detection interface please click save button to exit Anti dither System only memorizes one event during the anti dither period The value ranges from 0s to 15s Normal out There is 2 channel alarm...

Страница 119: ...Click this button to get device latest configuration information 7 3 2 8 PTZ PTZ interface is shown as in Figure 7 42 Please note before operation please make sure you have set speed dome address And...

Страница 120: ...resh Click this button to get device latest configuration information 7 3 2 9 Default Backup Default Restore factory default setup You can select corresponding items Backup Export current configuratio...

Страница 121: ...u can check the corresponding item here See Figure 7 44 Figure 7 44 Please refer to the following sheet for detailed information Parameter Function Format Clear data in the disk Read write Set current...

Страница 122: ...lease refer to the following sheet for detailed information Parameter Function Alarm output There are six output channels Multiple choices Activate Enable disable alarm output device After the Web act...

Страница 123: ...tup Manual Enable corresponding channel to record no matter what period applied in the record setup Stop Stop current channel record no matter what period applied in the record setup Operation here is...

Страница 124: ...124 7 3 3 5 Auto Maintenance Figure 7 47 Here you can select auto reboot and auto delete old files interval from the dropdown list See Figure 7 48 Figure 7 48...

Страница 125: ...ction Channel It is the monitor channel Snapshot mode There are two modes Timing and activation Frame rate You can select from the dropdown list The value ranges from 1f s to 7f s Resolution You can s...

Страница 126: ...ch The alarm output can delay for the specified time after alarm stops Then system disables alarm and corresponding activation output The value ranges from 10s to 300s Send email If you enable this fu...

Страница 127: ...k search button you can see an interface is shown as in Figure 7 52 Please select record playback mode and then select start time end time and channel Then please click search button you can see the c...

Страница 128: ...o download the file s to your local pc Figure 7 53 Now you can see system begins download and the download button becomes stop button You can click it to terminate current operation At the bottom of t...

Страница 129: ...eo Download type Download by file Select the file s and then click download button Download by time Download the recorded file s within your specified period Download Select the file you need multiple...

Страница 130: ...5 Fast play Playback device IP address and channel number Playback control bar Figure 7 56 7 5 Alarm Click alarm function you can see an interface is shown as in Figure 7 57 Here you can set device al...

Страница 131: ...s when peripheral device alarms Alarm Type External alarm Alarm input device sends out alarm Listen alarm System notifies web when alarm occurs you select from the above event type and then web can no...

Страница 132: ...e 7 59 You need to input user name and password to login again Figure 7 59 7 8 Un install Web Control You can use web un install tool uninstall web bat to un install web control Please note before you...

Страница 133: ...133 8 Professional Surveillance System Besides Web you can use our Professional Surveillance Software PSS to login the device For detailed information please refer to PSS user s manual...

Страница 134: ...environment is too harsh too much dust Hardware malfunction 3 System can not detect hard disk There are following possibilities HDD is broken HDD ribbon is damaged HDD cable connection is loose Main b...

Страница 135: ...There are following possibilities It is not a power picker It is not a power acoustics Audio cable is damaged DVR hardware malfunctions 9 There is audio when monitor but there is no audio when system...

Страница 136: ...le with Windows VISTA control ActiveX control has been disabled No dx8 1 or higher Please upgrade display card driver Network connection error Network setup error Password or user name is invalid Clie...

Страница 137: ...m Please upgrade your system 19 Alarm function is null There are following possibilities Alarm setup is not correct Alarm cable connection is not correct Alarm input signal is not correct There are tw...

Страница 138: ...ansformed to AVI via media player No DivX503Bundle exe or ffdshow 2004 1012 exe in Windows XP OS 23 Forget local menu operation password or network password Please contact your local service engineer...

Страница 139: ...orage capacitymi which is storage of each channel needed unit Mbyte mi qi hi Di 2 In the formula hi means the recording time for each day hour Di means number of days for which the video shall be kept...

Страница 140: ...Maxell USB Flash Stick 512M Maxell USB Flash Stick 1G Maxell USB Flash Stick 2G Kingax Super Stick 128M Kingax Super Stick 256M Kingax Super Stick 512M Kingax Super Stick 1G Kingax Super Stick 2G Neta...

Страница 141: ...ung TS H653A SATA DVD RW Panasonic SW 9588 C SATA DVD RW Sony DRX S50U USB DVD RW BenQ 5232WI USB DVD RW Appendix C Compatible CD DVD Burner List NOTE Please upgrade the DVR firmware to latest version...

Страница 142: ...ST3320620SV 320G SATA Seagate SV35 2 ST3500320SV 500G SATA Seagate SV35 2 ST3750640SV 750G SATA Seagate SV35 3 ST31000340SV 1T SATA Maxtor DiamondMax 20 STM3320820AS 320G SATA Maxtor DiamondMax 20 STM...

Страница 143: ...igital Cariar SE16 WD4000KD2 400G SATA Western Digital Cariar SE16 WD3200KS2 320G SATA Western Digital Cariar SE16 WD2500KS2 250G SATA Western Digital RE series WD5000ABYS 500G SATA Western Digital Ca...

Страница 144: ...22 inch wide screen LENOVO CRT LXB FD17069HB 17 inch LENOVO CRT LXB HF769A 17 inch LENOVO CRT LX GJ556D 17 inch Samsung LCD 2494HS 24 inch Samsung LCD P2350 23 inch Samsung LCD P2250 22 inch Samsung...

Страница 145: ...t emphasizing the all round protection including building transmission cable device ground and etc There shall be comprehensive management and the measures shall be scientific reliable practical and e...

Страница 146: ...s many modes but the selection depends on the system structure and performance The following are some successfully experience from our past work One point ground In the following figure you can see th...

Страница 147: ...onsidering the earthing you need to think about two aspects The first is the system compatibility and the other is the external interference coupling into the earth circuit which results in system err...

Страница 148: ...148 The monitor system usually can adopt the one point ground Please connect the ground end of 3 pin socket in the monitor system to the ground port of the system protection ground cable...

Отзывы: