27
Figure 3-6
Parameter
Grounding Alarm
Ground line
Alarm Input
1, 2, …, 8. It becomes valid in low voltage.
1-NO C
,
2-NO C
,
3-NO C
Three NO activation outputs.
Relay Output
1,2,3,4: NO and C(Normally Open and Com)
5: NO,C and NC(Normally Open, Com, Normally Closed)
6: Ctrl 12V(This is used for reset the senor)
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120
T
Ω
between A/B cables if there are
too many PTZ decoders.
T
3.7.2 Alarm Input Port
Please refer to the following sheet for more information.
z
4/8/16-ch grounding alarm inputs. (Normal open or Normal close type)
z
Please parallel connect COM end and GND end of the alarm detector (Provide external
power to the alarm detector).
z
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
z
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
z
Use the same ground with that of DVR if you use external power to the alarm device.
Figure 3-7
3.7.3 Alarm Output Port
z
3 ways relay alarm output (NO contact). Provide external power to external alarm device.
z
To avoid overloading, please read the following relay parameters sheet carefully.
z
RS485 A/B cable is for the A/B cable of the PTZ decoder.
Relay Specification
Model:
JRC-27F
Material of the
touch
Silver
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Rating
(
Resistance
Load
)
Maximum switch voltage
250VAC, 220VDC