background image

CONNECTIONS & CONTROLS

1. BALANCED INPUT

– Xtant1.1i amplifiers feature RCA type input connec-

tions. Source units with an output signal level of 100mV–17V may be used. The
balanced input serves two purposes. First, it helps eliminate noises being
induced into the signal path by isolating the signal ground from amp chasis.
Second, it allows use of any source unit.

2. GAIN

– This feature is used to fine-tune the input sensitivity of the 

amplifier to the source unit’s output level.

3. SPEAKER CONNECTION 

– These output terminals are individually labeled

for proper speaker connections.

4. POWER TERMINALS

– This is the main power connection for the amplifi-

er. The power and ground wire size should be the same gauge. 

GND

– The ground wire from this connection must be attached 

to bare metal on the vehicle.

REM

– To turn the amplifier on/off, this terminal must be connected

to the source unit’s "remote or electric antenna" wire. 

+12V

– The power wire from this connection must be attached 

to an inline fuse, then to the positive side of the vehicle battery. 

WARNING: An outboard fuse must be installed in-line with the power wire within
18 inches of the battery.

5

xtant.com

Xtant1.1i Amplifier Owner’s Manual

PERFORMANCE FEATURES

AUDIOPHILE FULL SPECTRUM CLASS D TECHNOLOGY

The Xtant1.1i adds local and global multiple nested feedback loops with premium MOSFETs and
OPAmps for switching stability and audio signal accuracy within the full range spectrum. This
results in an extremely high switching speed—over 1MHz.

Because the switching speed is over 1MHz, we are able to set the output filter frequency high
enough to avoid any phase related distortion within the higher frequency range of the audio sig-
nal. This enhances the musical reproduction by ensuring the higher frequencies (cymbals and
the like) compliment the entire frequency range to bring new realism to the Class D amplifier
sound experience.

The Audiophile Full Spectrum Class D Technology with Xtant’s attention to detail results in a
Class D amplifier that sounds better than many audiophile Class A/B amplifiers. It exhibits an
extremely low noise floor eliminating the “hiss” common to many Class D amplifiers. The
improved dynamic range enables the accurate reproduction of every loud and quiet passage
within the musical range. This makes the amplifier exceptionally suited for musical and theater
applications.

FULLY REGULATED PWM POWER SUPPLY

Xtant amplifiers feature a Fully Regulated, Pulse Width Modulated power supply. This power 
supply technology provides high efficiency and consistent output performance even when 
battery voltage is less than optimum.

BALANCED INPUT

The Balanced input circuit increases common mode noise rejection and eliminates ground loop
noise while allowing for 100mv to 17 volts of signal input. This circuit also makes interfacing
with any factory head-unit easy.

ADVANCED PROTECTION CIRCUITRY

Both Thermal and Overcurrent protection are incorporated into Xtant amplifiers. In the event of
a problem, the amplifier will reduce its power to maintain operation.

SMALL FOOTPRINT

These small footprint mono-block amplifiers are ideal for vehicles that have limited space and
allows for unlimited installation creativity in any application. The mono-block concept also allows
for easy audio and/or video system configuration (2-, 3-, 4-, 5-, 6-, or 7-Channel).

OPTIONAL PERFORMANCE ENHANCEMENTS

HIGH LEVEL ADAPTER (HLA)

High Level Adapters allow you to connect a source unit with speaker level outputs to your Xtant
amplifier.

4

3

2

1

All manuals and user guides at all-guides.com

Содержание 1.1I

Страница 1: ...Xtant1 1i Amplifier Owner s Manual All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...that your new Xtant product s and all of your mobile audio products be installed by your Authorized Xtant retailer In the event you decide to install your new Xtant product s please take the time to...

Страница 3: ...he audio sig nal This enhances the musical reproduction by ensuring the higher frequencies cymbals and the like compliment the entire frequency range to bring new realism to the Class D amplifier soun...

Страница 4: ...CAs from source unit speaker wires etc away from power wires power ground etc to avoid ground loops and other sources of noise INSTALLATION Any deviation from the connection specifications recommended...

Страница 5: ...ltage should measure between 11 V 15 V If the measurement is beyond this range have the source unit checked ou by an authorized dealer SYMPTOM Power without sound with red power indicator on SOLUTION...

Страница 6: ...t accessoires Xtant doivent tre install s par un sp cialiste professionnel agr par Xtant pour l installation du mat riel audio mobile Xtant Technologies vous conseille de faire installer les produits...

Страница 7: ...galement l interfa age avec n importe quelle unit de t te d usine CIRCUITERIE DE PROTECTION AVANC E Both Thermal and Overcurrent protection are incorporated into Xtant amplifiers In the event of a pro...

Страница 8: ...fils au dessous ou l ext rieur de la carrosserie du v hicule Faire passer les fils de signaux raccordements RCA l appareil source fils de hauts parleurs etc l cart des fils de puissance alimentation...

Страница 9: ...le c ble sur toute sa longueur et l ampli contre les court circuits Si le court circuit est sur l alimentation r parer la S il est dans l ampli retourner chez votre revendeur Xtant V rifier la tension...

Страница 10: ...icadores y accesorios Xtant han sido dise ados para ser instalados por un profe sional especialista en instalaci n de sistemas de audio m vil Xtant Technologies recomienda que un minorista autorizado...

Страница 11: ...de 100 mV a 17 V Este circuito tambi n facilita el establecimiento de la interfaz con unidades originales de f brica CIRCUITOS DE PROTECCI N AVANZADA Both Thermal and Overcurrent protection are incorp...

Страница 12: ...les RCA de la unidad fuente cables de altavoces etc lejos de los cables de alimentaci n alimentaci n tierra etc para evitar bucles de conexi n a tierra y otras fuentes de ruido INSTALACI N Toda desvia...

Страница 13: ...el conductor de encendido y apagado ON OFF del control a distancia El voltaje debe estar entre 11 15 voltios Si la lectura est fuera de estos l mites haga que un distribuidor autorizado revise la unid...

Страница 14: ...ezeichnete Wahl getroffen Willkommen bei Xtant NSTALLIEREN DES XTANT VERST RKERS Alle Xtant Verst rker sowie s mtliches Zubeh r sollten von einem qualifiziertem durch Xtant autorisierten Installations...

Страница 15: ...nnerhalb des h heren Frequenzbereichs des Audiosignals zu vermeiden Der Musikgenuss wird dadurch weiter verbessert dass die h heren Frequenzen Becken u den gesamten Frequenzbereich erg nzen und so den...

Страница 16: ...t1 1i SCHUTZEINRICHTUNGEN Alle Xtant Verst rker sowie s mtliches Zubeh r sollten von einem qualifizierten durch Xtant autorisierten Installationstechniker f r mobile Audio Systeme installiert werden X...

Страница 17: ...Verst rker aus und berpr fen Sie alle Eingangs und Ausgangssignalkabel und Anschl sse berpr fen Sie die Lautsprecher auf Kurzschl sse verwenden Sie hierzu einen Spannungsmesser oder schlie en Sie die...

Страница 18: ...or alterations of any nature Warranty does not extend to cosmetics or finish Before presuming a defect is present in the product be certain that all related equipment and wiring is functioning proper...

Страница 19: ...tant com XTT001425 RevA 9 02 NDM232 2002 Xtant Technologies All rights reserved Xtant is a registered trademark of Mitek Corporation Due to continual product development all specifications are subject...

Отзывы: