X|Smart™ Users Manual
Page 12
X Stream Designs, Inc.
3.1 Control Window
The Control Window is comprised of the Status Pane, Navigation Tabs, Live Stream Window, Fluid Level Meter, CID Control Pane,
Accessory Power Control Pane, Climate Control Pane and Power and Temperature Graphs. Each section of the control window
and what is displayed can be customized as desired by the user within the CONTROL INTERFACE tab.
Status Pane
This section of the control window displays the System Name, Time/Date, Enclosure Model, Exterior Temperature (If exterior tem-
perature probe is installed), Interior Temperature, Input Voltage, Input Current and Load. By default, the system displays tempera-
ture in both Fahrenheit and Celius. This can be changed to ºF, ºC or both as well as what is displayed in the status pane within the
CONTROL INTERFACE and SYSTEM SETTINGS navigation tabs.
Navigation Tabs
The navigation tabs allow the user to navigate from the Control Window to system setup menus. When
fi
rst navigating to either
the CONTROL INTERFACE tab or the SYSTEM SETTINGS tab, the system will ask for a username and password. The default user-
name is
admin
and the default password
xsd
(password is case sensitive).
Live Stream Window
The Live Stream WIndow streams live RTMP streams. It can be enabled and disabled from within the Control Interface tab. RTMP
URL setttings are entered in the System Settings tab. This feature DOES NOT allow you to display live video from typical IP net-
work cameras unless they support RTMP streaming.
Fluid Level
The Fluid Level meter displays the level of the washing
fl
uid at
four levels - FULL, 2/3, 1/3 and RESERVE. When the
fl
uid bottle is
fi
lled completely, FULL will be displayed for approximately 15 wash
cycles. 2/3 will then be displayed until approxmiately 30 wash
cycles are completed. 1/3 will then be displayed until approxi-
mately 50 wash cycles are completed. When no bar is displayed
in the meter, the
fl
uid bottle has reached the RESERVE level. This
happens at approximately 70 was cycles with approximately 20
was cycles remaing.
Note:
There is no indicator as to when the
fl
uid bottle is completely
empty. Damage to the system components can occur if the system
runs out of
fl
uid and continued attempts
are made to clean the dome.
Figure 3.1 - Fluid Level Meter
Figure 3.2 - CID Control
CID Control Pane
It is within this section of the Control Window that the user con-
trols the dome washing function and the dome wiping function
of X|Rain and X|Clear model enclosures. In the X|Clear model
enclosure, the CID Control Pane will display both Wash and Wipe
functions. In the X|Rain model enclosure, the CID Control Pane
will only display the Wipe function. If the X|Smart_PSP system is
installed in the X|Heat, X|Cold or X|Mod enclosures as an option,
the CID Control Pane will not be displayed.
Содержание XSmart PSP
Страница 1: ...X Smart PSP Users Manual Revision 1 2...