![Xstream HW152EMD Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/xstream/hw152emd/hw152emd_operation-manual_3672691026.webp)
26
maintenance
Storage & Maintenance Instructions
SPECIFIC MAINTENANCE
PUMP: Change the pump oil after the first 50 hours of operation. After
initial change, every 3 months or 250 hour intervals are recommended.
If oil appears dirty or milky, changes may be required in greater
frequency. Use pump oil SAE20 or 30 and fill only to the center of the
oil sight glass. DO NOT overfill.
QUICK COUPLERS: There are o-ring seals inside the couplers which
will deteriorate. To replace, simply install a replacement o-ring to
correct the leak. (Additional o-rings can be purchased from your
dealer.)
NOZZLE: Water flow through the spray nozzle will erode the orifice,
making it larger, resulting in a pressure loss. Nozzles should be
replaced whenever pressure is less than 85% of the maximum. The
frequency of replacement will depend upon such variables as mineral
content in the water and number of hours the nozzle is used.
BURNER AIR ADJUSTMENT: The air shutter has been factory preset
for proper operation between sea level and 2000 feet elevation at
standard conditions (60°F ambient water and air temperatures). To
assure maximum combustion efficiency at colder temperatures and
higher altitudes, it will be necessary to adjust the air supply to the
combustion chamber. A smoke spot test is recommended during any
air shutter adjustment. This will aid in maximizing the burner efficiency
and avoid the inefficient operation and excessive sooting of the
combustion chamber.
1. The machine must be running and the burner on.
2. Take a smoke spot test to determine if more or less air is required for
proper combustion.
a. If the test is greater than a #3 smoke, turn the shutter arm
counterclockwise to increase the air flow into the combustion
chamber.
b. If the test is yellowish in color, turn the shutter arm clockwise to
decrease the air flow into the combustion chamber.
3. Hold onto the air shutter adjusting arm and loosen the locking nut.
Move the shutter in 1/8” increments and retighten the locking nut after
each 1/8” movement.
4. Trigger the gun on and off slowly to make sure there is proper ignition.
Slight or no puffing on the ignition, and a smoke spot test of 0-3 is
good.
5. Repeat steps 2 and 3 until step 4 is attained.
LEAKS: Promptly eliminate any leaks found in the pumping system by
removing suspect parts, applying thread sealant to the threads and
reinstalling.
Содержание HW152EMD
Страница 1: ...operation manual HW152EMD HW204EMD ELECTRIC HOT WATER PRESSURE WASHER...
Страница 36: ...36 flow chart 57 6 013 FLOW CHART parts list...
Страница 38: ...38 frame assembly 59 10 Copyright 2013 FRAME ASSEMBLY parts list...
Страница 40: ...40 motor pump assembly 61 12 Copyright 2013 MOTOR PUMP ASSEMBLY parts list...
Страница 49: ...49 69 20 Copyright 2013 HEAT EXCHANGER BLOWER MOTOR heat exchanger blower motor parts list...
Страница 51: ...51 boiler assembly 71 22 pyright 2013 BOILER ASSEMBLY parts list...
Страница 62: ...62 wire schematic for hw204emd 83 34 ht 2013 WIRE SCHEMATIC FOR C204EMHW HW204EMD parts list...
Страница 63: ...63 wire diagram for hw204emd 84 35 Copyright 2013 WIRE DIAGRAM FOR C204EMHW HW204EMD parts list...
Страница 66: ...66 If you need assistance with the assembly or operation of this Pressure Washer please call 1 866 770 1711...