Document MT0605P.E
© Xsens Technologies B.V.
MTi User Manual
76
7
Important notices
7.1 Safety instructions
It is recommended to study the instructions below
Do not place the MTi near strong magnetic fields.
Do not use cables or connectors other than described in this manual.
7.2
Absolute maximum ratings
Stresses above Absolute Maximum Ratings may cause permanent damage to the device.
Shock (any axis):
20000 m/s
2
(2000 g) 0.5 ms (half-sine)
Standard Input Voltage:
-
0.3 V … 40 V
Alternative Input Voltage:
3.3 V +/- 0.1 V
Interface inputs:
-
25 V … 25 V (RX, A and B inputs)
-
0.3 V …3.6 V (alternative UART)
SyncIn:
0
– 20 V
Bidirectional SyncIn:
0 - 3.6V
Operating/Storage Temperature:
-40
C … 85
C
Humidity:
Casing is IP67 (for OEM: 95% max, non-condensing)
Stresses beyond those listed here may cause permanent damage to the device. These are stress
ratings only, and functional operation of the MTi at these or any other conditions beyond those
indicated in section 4.6 of the specifications is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
NOTE: Drops onto hard surfaces can cause shocks of greater than 20000 m/s
2
(2000 g) exceed the
absolute maximum rating of the device. Care should be taken when handling to avoid damage. Drops
causing shock greater than absolute maximum ratings may not destroy the device but will permanently
alter the properties of the physical motion sensors, which may cause the device to become inaccurate.
7.3 Maintenance
The MTi will not require any maintenance if properly used (see also section 7.1 and 7.2). However, if
the Motion Tracker is not functioning according to the specifications please contact Xsens or your local
distributor (
www.xsens.com/support
).