42
4.9.5
Uncalibrated raw output mode
The MTi can output sensor component readout (SCR), i.e. digitized voltages of all sensors, before
they are filtered or calibrated using Xsens’ proprietary firmware and calibration parameters. These
sensors are the gyroscopes (rate of turn), accelerometers (acceleration), magnetometer (magnetic
field), barometer (static pressure) and temperatures (gyroscope temperatures and a general
temperature sensor). When selecting sensor component readout, the following outputs are available:
Sensor
Digital/analog
Unit
Maximum frequency
Gyroscopes
Analog sensor, 16 bit ADC
2-byte integer
2000 Hz
Accelerometers
Analog sensor, 16 bit ADC
2-byte integer
2000 Hz
Magnetometer
Digital sensor
a.u.
100 Hz
Barometer
Digital sensor
Pa
50 Hz
Temperature sensors
Analog sensor, 12 bit ADC
ºC
1 Hz
Note that these SCR-values of the gyroscopes and accelerometers are not calibrated for offset, gain,
misalignment and temperature. Also, coning and sculling compensation is not applied. It is possible to
post-process SCR data with MT Manager, and this output is very suitable if you need to perform your
own calibration. Note that this output cannot be combined with any other output.