The rest of the software setup is the same as described above. However, instead of
clickingRecord in Xsens software, one should click the hardware trigger supplied by
Noraxon, to generate a manual trigger to both systems.
5.1.3
XSens Software
1.
In the Configuration window, in the Sync tab you should select:
Strat recording (in)
Stop Recording (in)
•
In 1
•
Polarity: Rising Edge
•
Skip Factor = 1
•
Skip First = 0
•
Delay = 0 ms
•
Trigger once: uncheck
•
In 1
•
Polarity: Rising Edge
•
Skip Factor = 1
•
Skip First = 1
•
Delay = 0ms
•
Trigger once: uncheck
To initialize recording, click the record button.
The normal red dot icon will change to a pause symbol, indicating that the software is
waiting for an external pulse.
Figure 10 - Motion Capture Configuration window in MVN Analyze. Setting on the sync tab.
Figure 11 - Record button. a) before clicking, b) after clicking, with sync-in activated.
Figure 9 - Configuration of TeleMyo mini-receiver in Noraxon MyoResearch software.