background image

18

www.XSscuba.com

Care and Maintenance 

1. 

Soak, or rinse, in fresh water

 

        a. Unit pressurized:

i. Ideally, you should leave 

your MultiMax pressur-

ized with air and soak 

it in warm, fresh water. 

While still pressurized, 

cycle each of the buttons 

repeatedly. 

 

ii. If a warm water soak is 

not available, rinse with 

tap water from a garden 

hose with a low-pressure 

nozzle. Let the water flow 

into the mouthpiece and 

out the exhaust port 

         

b. Unit unpressurized:

 

i. Soak or rinse with tap 

water from a garden 

hose with a low-pressure 

nozzle. Let the water flow 

into the mouthpiece and 

out the exhaust port.

 

ii. 

Do not depress the 

purge button!

 Depressing 

the purge button allows 

water to back flow into 

the breathing valve. This 

can leave mineral depos-

its and/or contaminants. 

This can accelerate the 

time until the next service. 

2. 

After rinsing, shake any 

excess water out of the unit. 

Содержание MultiMax

Страница 1: ...1 www XSscuba com Owner s Manual www XSscuba com Multiple Functions Maximum Performance...

Страница 2: ...2 www XSscuba com Owner s Manual...

Страница 3: ...tion 11 Operating the MultiMax 14 Inflation Deflation Use as An Alternate Air Source Clearing Pre Dive Inspection 16 Care and Maintenance 18 Dealer Inspection and Service 19 Warranty 20 MultiMax Speci...

Страница 4: ...ltiMax is a quality product built to the highest standards The MultiMax is a product of quality design and engineering material selection and precise assembly methods Each unit is 100 tested prior to...

Страница 5: ...first stage of the regulator to the MultiMax where it connects using a large flow connector This hose is different from a traditional inflator hose due to its larger inner diameter which promotes adeq...

Страница 6: ...s which are accompanied by the following symbols A WARNING indicates any situation that if not avoided could result in serious injury or death A CAUTION indicates any situation or technique that could...

Страница 7: ...ead and understand all of the instructions provided in this owner s manual Should you have any questions or do not completely understand these instructions consult your Authorized XS Scuba Dealer or c...

Страница 8: ...t If any signs of damage or malfunction are found do not dive with the MultiMax until it has received service from an authorized XS scuba dealer WARNING The MultiMax is designed for use in water that...

Страница 9: ...x is essentially a low pressure device operating below 145 psi 10 bar there is no concern about using it with enriched air nitrox It is not held to the same rigid standards as a regulator s first stag...

Страница 10: ...ww XSscuba com Your MultiMax at a Glance High flow hose Oral inflation deflation button Corrugated hose connector with cable retaining pin Quick connect fitting Dust cap Power inflation button Purge F...

Страница 11: ...e its size and threads should not be compatible with a high pressure port on a modern first stage there are older models and adapters that would allow this mistake to be made 1 If attached remove the...

Страница 12: ...e cutter pliers avoiding contact with the corrugated hose b Pull or twist the inflator from the corrugated hose NOTE In some cases the inflator may be glued in place with rubber cement If this is the...

Страница 13: ...a 3 4 19 mm inner diameter corrugated hose Again using an awl or similar tool push out the cable retaining pin halfway Loop the eye of the cable over the retaining pin and insert the pin back into th...

Страница 14: ...mply depress the blue button in short bursts as needed to route air from you cylinder into your BC ii Oral inflation which is less common is done by placing your mouth over the mouthpiece fully depres...

Страница 15: ...he large gray inflation deflation button allowing air to escape out of the mouthpiece Release the button to close the valve NOTE While using method ii do not continue depressing the oral button after...

Страница 16: ...g the MultiMax as your second stage regulator all inflation and deflation procedures as outlined in this manual are still applicable WARNING Never push the deflation button during use of the MultiMax...

Страница 17: ...equate volume of air with little effort Afterward it should not leak air It should be silent 6 Close the cylinder valve and purge the remaining air in the hoses Place the MultiMax in your mouth and tr...

Страница 18: ...with a low pressure nozzle Let the water flow into the mouthpiece and out the exhaust port b Unit unpressurized i Soak or rinse with tap water from a garden hose with a low pressure nozzle Let the wat...

Страница 19: ...i above 5 Store the MultiMax in a ventilated cool dry place out of direct sunlight CAUTION DO NOT store your regulator in a hot environment or near an electric motor which produces ozone Prolonged exp...

Страница 20: ...ur personal safety and the mechanical integrity of your MultiMax may depend on it WARNING Do not attempt to disassemble or repair the MultiMax Disassembly and service of the MultiMax must only be perf...

Страница 21: ...regular basis Replace ment of these items is usually necessitated based upon normal wear rather than defects 6 This warranty does not extend to damages caused by improper use improper maintenance negl...

Страница 22: ...aler Be sure to save your sales receipt along with proof of prior service XS SCUBA DISCLAIMS AND EXCLUDES ANY LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states in the U S and some foreign...

Страница 23: ...ess Steel Demand Valve Chrome plated Brass Weight w o QD and hose 5 3 oz 150 g Average Flow Rate 340 liters min Demand Valve Design Downstream Venturi assisted Working Pressure 125 150 psi 8 6 10 5 ba...

Страница 24: ...24 www XSscuba com ANNUAL SERVICE RECORD Date Dealer s Name Technician s Name Service Performed...

Страница 25: ...25 www XSscuba com...

Страница 26: ...26 www XSscuba com RM 0342 rev 19A www XSscuba com...