A–1
A
Specifications
Appendix A contains electrical performance and physical specifications
for the XM 1000 and XM 1800.
Specifications are subject to change without notice.
Electrical Performance
XM 1000
XM 1800
Output power at 77 º F (25 ºC) ambient
temperature and 12 VDC input:
• Maximum continuous output power
• 5 minutes
1000 W
1200 W
1800 W
n/a
Surge rating
2000 W
3600 W
Output voltage
115 VAC RMS ± 10
Output waveform
Modified sine wave
Output frequency
60 Hz ± 1 Hz
DC input voltage range
10.5–15.5 VDC
DC low voltage alarm
11.0 V
DC low voltage cutout
10.5 V
DC low voltage recovery
12.0 V
Over-voltage cutout
15.5 V
AC pass-through low voltage cutout
90 V
AC pass-through low voltage recovery
100 V
Optimum efficiency
90%
No load power draw with inverter on
< 5 W
< 9 W
No load power draw with inverter off
< 1 W
Xantrex_PRO1800.book Page 1 Tuesday, April 24, 2007 11:33 AM
Содержание XM 1800
Страница 2: ...Xantrex PRO Inverter Owner s Guide...
Страница 13: ...xii...
Страница 19: ...2 4...
Страница 47: ...3 28...
Страница 55: ...4 8...
Страница 61: ...5 6...
Страница 64: ...Mounting Dimensions 975 0263 01 01 A 3 Mounting Dimensions Figure A 1 XM 1800 Mounting Dimensions...
Страница 65: ...Specifications A 4 975 0263 01 01 Figure A 2 XM 1000 Mounting Dimensions...
Страница 77: ...C 4...