Introduction
1–2
975-0263-01-01
Comprehensive Protection
The XM 1800 is equipped with numerous protection features to guarantee
safe and trouble-free operation:
Low battery alarm
Alerts you if the battery has become discharged to
11.0 V or lower.
Low battery voltage shutdown
Shuts the XM 1800 down
automatically if the battery voltage drops below 10.5 V. This feature
protects the battery from being completely discharged.
High battery voltage shutdown
Shuts the XM 1800 down
automatically if the input voltage rises to 15.5 V or more.
Overload alarm
Alerts you if the loads connected to the XM 1800 are
close to the inverter’s operating limits.
Overload shutdown
Shuts the XM 1800 down automatically if the
loads connected to the inverter exceed the inverter’s operating limits or if
a short circuit is detected in the circuitry connected to the inverter’s
output.
Over-temperature alarm
Alerts you if the XM 1800 is running hot
and is approaching the over-temperature shutdown level.
Over temperature shutdown
Shuts the XM 1800 down automatically
if its internal temperature rises above an acceptable level.
These values and thresholds are set at the factory and cannot be adjusted.
Xantrex_PRO1800.book Page 2 Tuesday, April 24, 2007 11:33 AM
Содержание XM 1800
Страница 2: ...Xantrex PRO Inverter Owner s Guide...
Страница 13: ...xii...
Страница 19: ...2 4...
Страница 47: ...3 28...
Страница 55: ...4 8...
Страница 61: ...5 6...
Страница 64: ...Mounting Dimensions 975 0263 01 01 A 3 Mounting Dimensions Figure A 1 XM 1800 Mounting Dimensions...
Страница 65: ...Specifications A 4 975 0263 01 01 Figure A 2 XM 1000 Mounting Dimensions...
Страница 77: ...C 4...