Installation
3–20
975-0263-01-01
In this wiring diagram, the AC input comes from the main AC panel which
acts as the circuit breaker from an AC source. The output is routed to a
separate circuit breaker acting as the inverter AC subpanel.
Figure 3-6
AC Wiring Diagram with an Inverter Subpanel
GENERATOR
SHORE POWER
TO DC LOADS
AC
IN
AC
OU
T
GN
D
GN
D
CA
UT
ION
!
Do
not
con
nect
the
AC
OU
Tto
any
oth
er
sou
rce
ofp
owe
r. D
am
age
to u
nit
may
occ
ur.
N
L
L
N
TRANSFER SWITCH
AC OUTLETS
MAIN AC PANEL
INVERTER SUBPANEL
CAUTION!
Do not connect the AC OUT to any other
source of power. Damage to unit may occur.
INVERTER LOADS
Note: Do NOT connect the
AC OUT Neutral and Line to the
AC IN Neutral and Line.
Xantrex_PRO1800.book Page 20 Tuesday, April 24, 2007 11:33 AM
Содержание XM 1800
Страница 2: ...Xantrex PRO Inverter Owner s Guide...
Страница 13: ...xii...
Страница 19: ...2 4...
Страница 47: ...3 28...
Страница 55: ...4 8...
Страница 61: ...5 6...
Страница 64: ...Mounting Dimensions 975 0263 01 01 A 3 Mounting Dimensions Figure A 1 XM 1800 Mounting Dimensions...
Страница 65: ...Specifications A 4 975 0263 01 01 Figure A 2 XM 1000 Mounting Dimensions...
Страница 77: ...C 4...