https://www.XPOtool.com
Item 63021
Page 6
The Tool Experts
05 2022-1
Operation and storage
Turning on the heater
1.
Turn the valve on the gas bottle fully open.
2.
Press the rotary control switch and turn it counter-clockwise to “PI OT.”
3.
Press the rotary control switch in and hold it down for 90
s. Meanwhile, press the ignition switch
several times until a pilot flame starts to burn. Release the rotary control switch when the flame
burns.
Notes:
◦
If a new gas container has been connected, wait at least one minute until the air in the gas
line has escaped.
◦
When igniting the pilot flame, make sure that the rotary control switch is held down the entire
time you operate the ignition switch. When the burns, the rotary control switch can be re-
leased again.
◦
The pilot flame can be observed and checked through the small round window; to do this,
the cover at the lower end of the flame protection grille must be pushed to the side (to the
left or right of the control unit).
◦
If the pilot flame does not ignite or goes out again, repeat step 3.
4.
After igniting the pilot flame, turn the rotary control switch to the highest setting for 5
min; then
you can set it to the temperature desired.
Rotary control switch
Igniter
Turning out the heater
1.
Set the rotary control switch to “PI OT.”
2.
Press the rotary control switch and turn it to “OFF.”
3.
Completely close the valve on the gas bottle.
Storage
1.
Close the gas cylinder valve after use or in the event of a malfunction.
2.
Remove the pressure reducing valve and the gas hose.
3.
Check the gas valve for leaks and damage. If you suspect damage, have the seller replace it.
4.
Never store PG cylinders in basements or in places without adequate airflow.
Cleaning and care
•
Wipe powder-coated surfaces with a soft, damp cloth. Do not clean the heater with flammable
or corrosive cleaning agents.
•
Remove debris from the burner to keep it clean and safe to use.
OFF
IGNITER