- 14 -
1. Route the power cord to the junction box.
2. Using listed conduit fittings and connectors, connect the power supply to the box and
each line to the appropriate wire following this color convention:
BLACK = HOT LEG
WHITE = NEUTRAL
GREEN/YELLOW = GROUND
Polarity must be observed.
Unit must be properly grounded.
Use a double throw disconnect switch.
3. Replace the box cover
Replace the Anti-grease flters.
All wiring must be in compliance with national electrical code, ANSI/NFPA 70-1999
and all local codes and regulations.
electrical connection
A
Remove the central screw and lift the electrical plant box.
B
Remove the 3 fixed screws. Then position the electrical box so it is in line with the holes
of the previously removed screws and tighten.
C
Pay attention that the tear tape of the electrical box is inside the slot and then tighten screw.
A
B
C
D
D
Содержание XOM30GC
Страница 1: ...I worked really hard on this manual so please read it XOM WALL MOUNT MODELS XOM30GC XOM36GC ...
Страница 2: ......
Страница 21: ...J ai travaillé très dur sur ce manuel veuillez donc le lire XOM WALL MOUNT MODÈLES XOM30GC XOM36GC ...
Страница 40: ...He trabajado mucho en este manual así que léalo XOM WALL MOUNT MODELOS XOM30GC XOM36GC ...
Страница 59: ......
Страница 60: ...3011000130300 00 ...