XM1240S AT Commands Reference Manual
No. XM1240S-A00-106
xmodus swiss GmbH
26 / 46
4.4.14 S43 - Connect Message format
S43 selects the format of the CONNECT messages displayed after set up a connection.
The parameter, if valid, is written to S-Register bit 0,1 and 2. See AT%Vn Command for
configuration.
Range:
0 – 2 (Bit Mapped)
Default: 1
S43=0
CONNECT only.
S43=1
CONNECT (B-Channel protocol)
S43=2
CONNECT <Line-speed> (B-Channel protocol)
4.4.15 S44 - Extented Result Codes
S44 sets the types of result messages displayed after trying to set up a connection.
Please see also chapter 5 for a detailed description. The parameter, if valid, is written to
S-Register bit 0,1 and 2. See at ATXn Command for configuration.
Range:
0 –4 (Bit Mapped)
Default: 4
S44=0
ATX0 (see description of AT command ATXn)
S44=1
ATX1 (see description of AT command ATXn)
S44=2
ATX2 (see description of AT command ATXn)
S44=3
ATX3 (see description of AT command ATXn)
S44=4
ATX4 (see description of AT command ATXn)
4.4.16 S45 - Extented ISDN Result Codes
S45 sets the types of ISDN result codes displayed after set up a connection. Please see
also chapter 5 for a detailed description. The parameter, if valid, is written to S-Register bit
0,1 and 2. See at ATWn Command for configuration.
Range:
0 –3 (Bit Mapped)
Default: 0
S45=0
ATW0 (see description of AT command ATWn)
S45=1
ATW1 (see description of AT command ATWn)
S45=2
ATW2 (see description of AT command ATWn)
S45=3
ATW3 (see description of AT command ATWn)
All manuals and user guides at all-guides.com