XMG OASIS Скачать руководство пользователя страница 16

16

 

 

16. Transporting OASIS without draining… 

 

 

If you wish, for the sake of convenience, to transport XMG OASIS with 

liquid inside against the official recommendation, do this 

at your own 

risk

 and make sure to adhere to the following advice: 

 

Do NOT pack XMG OASIS together with any other electronics, 

sensitive equipment or delicate objects.

 Laptop and XMG OASIS 

must be transported separately, in two different bags. 

 

Place XMG OASIS on a towel or blanket to catch any residual fluid 

that might emerge during transportation. 

 

Make sure that the water tubes are 

NOT BENT EXCESSIVELY

 inside 

your bag, otherwise it will cause material damage and leakage over 

time. 

 

You must guarantee that XMG OASIS will always be kept upright 

during transportation. The refill port on top of XMG OASIS is not 

100% waterproof if the device is leaning sideways or upside down. 

Let us clarify again: such a mode of transportation is 

risky

 and will lead 

to liquid damage in case of accidents or negligence. 

 

Leakage may cause 

permanent damage

 to XMG OASIS and to 

surrounding electronics and sensitive objects. 

 

Liquid damage that is caused during transportation or any other 

inappropriate handling is 

NOT covered under warranty

. We assume 

NO 

LIABILITY

 for consequential damages to any items that are placed near or 

transported with XMG OASIS or its corresponding laptop. 

 

If there is a chance that the laptop or XMG OASIS may be exposed to 

environmental temperatures below 5 °C (41 °F) during travel and 

transportation, 

all liquid must be drained

 regardless of convenience. 

Liquid exposed to freezing temperatures may cau

se damage to pipes and 

connectors and will invalidate your warranty. 

  

   If you often commute between places (e.g. home and working place), 

please consider to 

buy additional units

 of XMG OASIS in order to avoid 

risky and inconvenient transportation. 

 

 

Transporting XMG OASIS with a significant amount of liquid 

inside the main unit and tubing is NOT recommended! 

 

Содержание OASIS

Страница 1: ...XMG OASIS The first portable laptop watercooling User Manual...

Страница 2: ...al laptop air cooling systems with similar power levels The system comes with accessories that are required for operation and maintenance Before transporting XMG OASIS or its host laptop all liquid mu...

Страница 3: ...tor power button LED 3 colors Communication Bluetooth Low Energy LE Power supply DC in powered by 19 5 V or 20 V laptop power adapter DC out forwards power to host laptop through DC cable Plug dimensi...

Страница 4: ...uct overview Front side view Left side view Back side view Right side view The power cord can be wrapped and stored around the base 1 drainpipe sockets 2 RGB LED 3 DC port 4 vents 5 power connector 1...

Страница 5: ...view 6 refill port cover 7 power LED indicator 8 power button Power LED indicator color codes blue blinking Bluetooth searching blue steady Bluetooth connected purple blinking Liquid Input Mode orange...

Страница 6: ...e in the original box of XMG OASIS 6 Gently attach the black connectors of the water tubes to the main unit by carefully tightening the screws Avoid twisting the tubes during this process Stop tighten...

Страница 7: ...nector is reversible meaning the orientation which tube connects to which port does not matter Connect it in such a way that the tubes do not get twisted Keep them straight and parallel do not bend th...

Страница 8: ...move from coolant liquid to distilled water it is recommended to fully empty all liquid from the coolant loop first You should NEVER fill in tap water mineral water or any other food liquid not even...

Страница 9: ...ndicating that it has entered Liquid Input Mode During this mode the pump will work to push liquid from the reservoir into the cooling loop 5 The water level behind the front lens will drop Add additi...

Страница 10: ...drop due to evapo ration Small drops of liquid are also lost when disconnecting the quick release connector from the laptop Please check the water level behind the front lens of the main unit on a re...

Страница 11: ...ve all fluids keep all surfaces clean and dry 6 Now close the rubber seal of the laptop This operation may cause additional liquid to be squeezed out around the edges and the ventilation hole of the r...

Страница 12: ...he drainage adapter towards a small container or tissue paper Slowly swerve left and right in order to release all liquid 4 To remove the last few drops of liquid put the laptop back into the horizont...

Страница 13: ...his bridge is not very stable If you accidentally pull on the tubes or the laptop possibly by accident but also by children or pets the two transparent little tubes of the drainage adapter will be pul...

Страница 14: ...ut Risk of freezing temperatures Environmental temperatures below 5 C 41 F might cause damage to pipes and connectors by freezing the liquid that is still trapped inside High risk of irreparable perma...

Страница 15: ...from the tubes 5 Carefully raise the main unit with one hand while still aiming the tubes into your container Let gravity assist the process 6 When the liquid stops flowing gently tilt the main unit...

Страница 16: ...such a mode of transportation is risky and will lead to liquid damage in case of accidents or negligence Leakage may cause permanent damage to XMG OASIS and to surrounding electronics and sensitive ob...

Страница 17: ...inside the tubes or around the pump With the tubes connected to your laptop enter Liquid Input Mode a few times This might help to disperse air bubbles inside the system Alternatively follow the inst...

Страница 18: ...uid in the process When full a tilt angle of 29 degree is enough to cause the device to tip over to the side This may cause considerable amounts of liquid to escape from the refill port on the top of...

Страница 19: ...drain all liquid from the device disconnect the tubes from the device reconnect the hexagon water stoppers to the front of the device The device must be tilted at different angles to be fully drained...

Страница 20: ...ce manual A service manual with disassembly steps is located in the download portal on our website The service manual is for reference only and does not express an encouragement to disassemble the dev...

Страница 21: ...you find no more fluids with fresh dry tissue tips 9 Disconnect the water tubes from the laptop without moving the laptop Dry off the water ports See page 11 for details 10 Leave the laptop in this po...

Страница 22: ...ring up the device Do not power on the device if there is no liquid inside the device If the tubes are connected to the laptop but water is not flowing i e if OASIS is not operating the connector may...

Страница 23: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Страница 24: ...24 Scan this code to find your answer in our FAQ Contact Schenker Technologies GmbH Walter K hn Str 2C 04356 Leipzig GERMANY E Mail support xmg gg Do you have any more questions...

Отзывы: