Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
27
OVEN TROUBLESHOOTING
LUI Service Error Codes
Display Alarm
MC LED
Error Determination
Troubleshooting
Oven Probe
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
Temp Sensor Error, Open or Short.
Temp <40F (4C) or >700F (371C)
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
PCB Temp Probe
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
Temp Sensor Error, Open or Short.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Ignition Error
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
From Ignition enable (run) signal, if
oven doesn’t see 25F (-4C) temp
rise in three (3) minuites. If restart
(actual temp within 50F (10C) of set
point) error timing ten (10) minutes.
Check To See If Gas Hose Is Connected.
Next, Is Exterior Gas Valve On? If Yes,
Perform A Hard Reset. If No, Turn Gas
Valve On. If Error Still Exists, Contact XLT.
Over Temp
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
Temp is 50F (10C) over set point
for period > one (1) minute. If user
adjusts set point lower, inhibit alarm
until new set point is reached.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Under Temp
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
Once set point is reached, the Actual
is 15F (-9C) under set point for
more than thirty (30) minutes. If user
adjusts set point, reset timer.
Check To See If Gas Hose Is Connected.
Next, Is Exterior Gas Valve On? If Yes,
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Over Speed
Alarm LED on. Flash
CONVEYOR LED. All other
LED's operate as normal.
Speed > thirty (30) seconds fast
Duration vs. Set Point
Perform A Hard Reset. If Error Still Exists,
Check LUI Settings. If Settings Are Correct,
Perform A Pan Test To Confirm Settings. If
Error Still Exists, Contact XLT.
Under Speed
Alarm LED on. Flash
CONVEYOR LED. All other
LED's operate as normal.
Speed > thirty (30) seconds slow
Duration vs. Set Point
Check Drive Chain and Sprocket To Verify
Proper Working Condition. Perform A Hard
Reset. If Error Still Exists, Check LUI
Settings. If Settings Are Correct, Perform A
Pan Test To Confirm Settings. If Error Still
Exists, Contact XLT.
Software Error
Alarm LED flash. All other
LEDs off.
Internal Software Error
Check for pinched wires. Perform A Hard
Reset. If Error Still Exists, Contact XLT.
EEPROM Error
Alarm LED flash. All other
LEDs off.
Bad Checksum
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Key Short
Alarm LED flash. All other
LEDs off.
Any Key Shorted > one (1) minute.
Clean LUI Screen. Perform A Hard Reset.If
Error Still Exists, Contact XLT.
Comm Error
Alarm LED flash. All other
LEDs off.
Internal Software Error
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Hi Alarm
Alarm LED on. Flash HEAT
LED. All other LED's operate
as normal.
Hi Alarm set point exceeded.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Main Fan Low
Amps
Alarm LED on. Flash FAN
LED. All other LED's operate
as normal.
Amps below min level per Main Fan
Amp level table for ten (10) seconds.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Main Fan High
Amps
Alarm LED on. Flash FAN
LED. All other LED's operate
as normal.
Amps above max level per Main Fan
Amp level table for ten (10) seconds.
Check CB1 To See If It Has Tripped. If Yes,
Reset CB1. If No, Perform A Hard Reset. If
Error Still Exists, Contact XLT.
Belt Jam
Conveyor LED flash. All other
LED's operate as normal.
If the current motor speed is less
than 25% of the most recent
minimum motor speed.
Check For Obstructions. If No Obstructions
Are Found, Check Drive Chain and Sprocket
To Verify Proper Working Condition.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Содержание 1832
Страница 11: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 11 This page is intentionally left blank ...
Страница 25: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 25 This page intentionally left blank ...
Страница 48: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 48 OVEN PARTS BASE 1 2 3 4 6 7 5 ...
Страница 61: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 61 This page intentionally left blank ...
Страница 67: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 67 This page intentionally left blank ...
Страница 78: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 78 OVEN SCHEMATIC WORLD 1 BOX 230 VAC LH ...
Страница 79: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 79 OVEN SCHEMATIC WORLD 1 BOX 230 VAC RH ...
Страница 86: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 86 OVEN SCHEMATIC WORLD 2 BOX 230 VAC LH ...
Страница 87: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 87 OVEN SCHEMATIC WORLD 2 BOX 230 VAC LH ...
Страница 88: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 88 OVEN SCHEMATIC WORLD 2 BOX 230 VAC RH ...
Страница 89: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 89 OVEN SCHEMATIC WORLD 2 BOX 230 VAC RH ...
Страница 90: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 90 HOOD SCHEMATIC STANDARD w FS w VFD ...
Страница 91: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 91 HOOD SCHEMATIC WORLD w FS w VFD ...
Страница 92: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 92 HOOD SCHEMATIC w oFS w oVFD ...
Страница 93: ...Technical Support US 888 443 2751 Technical Support INTL 316 943 2751 93 NOTES ...