XT2640 Operating Manual
13 July 2016
Page 155 of 187
Sub
‐
Field
Sub
‐
field
Format
Value
Description
STBYERR
Responds with standby power measurement error (in W)
Measurement Source
KEYWORD
CH1, CH2, CH3 or
CH4
CH1 is DEFAULT if no other Measurement Source sub‐field found
Data is from the selected channel
A1, A2, A3, VPA1,
VPA2 or VPA3
Data is from the selected VPA
MOTOR
Data is a motor measurement result (only the Data field is used with
this source, any other fields are ignored)
IN
Data is from the IN efficiency group (or starts at this group if 2
nd
Measurement Source is MIDDLE or OUT)
MIDDLE
Data is from the MIDDLE efficiency group (or starts at this group if
2
nd
Measurement Source is OUT)
OUT
Data is from the OUT efficiency group
2
nd
Measurement Source (ignored
if Measurement Source is a single
channel or is MOTOR)
KEYWORD
MIDDLE
Data is to the MIDDLE efficiency group (only valid if Measurement
Source is IN)
OUT
Data is to the OUT efficiency group (only valid if Measurement
Source is IN or MIDDLE)
pA … D
Data is from the 1
st
through 4
th
(resp.) channel of the selected VPA
pAC
Data is the voltage measured between phases A and C of the selected
VPA
pAB
Data is the voltage measured between phases A and B of the selected
VPA
pBC
Data is the voltage measured between phases B and C of the selected
VPA
pN
Data is the neutral current of the selected VPA
WYE
Data is the ‘Wye’ voltage of the selected VPA
DELTA
Data is the ‘Delta’ voltage of the selected VPA
SEQZERO
Data is the zero sequence data of the selected VPA
SEQPOS
Data is the positive sequence data of the selected VPA
SEQNEG
Data is the negative sequence data of the selected VPA
TOTAL or
AVERAGE
DEFAULT if no other 2
nd
Measurement Source sub‐field found
Data is the total for the selected VPA, except for VOLTS and AMPS
data which is the average of all channels/phases
Measurement Type
KEYWORD
DC
Data is the DC component
AC
Data is the AC component
ACDC or RMS
Data is the ACDC component
COUPLED
DEFAULT if no other Measurement Type sub‐field found
Data is the DC, AC or ACDC component as COUPLING setting
RECTIFIED
Data is the average rectified (ACDC)
STBY
Data is the average standby power measurement (ACDC)
STBYMIN
Data is the minimum standby power measurement (ACDC)
STBYMAX
Data is the maximum standby power measurement (ACDC)
STBYCFMIN
Data is the minimum crest factor standby power measurement
(ACDC)
STBYCFMAX
Data is the maximum crest factor standby power measurement
(ACDC)
STBYTHDMAX
Data is the maximum THD standby power measurement (as the
percentage of the fundamental)
STBYSLOPE
Data is the slope (in W/sec) of the standby power measurement
FF
Data is the form factor (ACDC)
CF
Data is the crest factor (ACDC)
PK
Data is peak (ACDC)
VALLEY
Data is valley peak (ACDC)
PK‐VLY
Data is the difference between peak and valley peak
HIPK
Data is the highest peak (including polarity, ACDC)
LOPK
Data is the lowest peak (including polarity, ACDC)
THDF
Data is THD relative to fundamental amplitude (in %)
THDSIG
Data is THD relative to ACDC amplitude (in %)
H1 … 500
Data is harmonic amplitude data for the specified harmonic
P1 … 500
Data is harmonic phase data for the specified harmonic (in degrees
with ±180° range)
INRUSH
Data is the inrush data (max hold, ACDC)
INRUSHPK
Data is the peak inrush data (max hold, PK data)
INRUSHVLY
Data is the valley peak inrush data (min hold, VALLEY data)
INTEG
Data is the integrated data (as COUPLING setting)
INTAVG
Data is the average integrated data (as COUPLING setting)
CHARGE
Data is the integrated charge data (DC only)
DISCHARGE
Data is the integrated discharge data (DC only)
BOUGHT
Data is the integrated bought data (as COUPLING setting)
SOLD
Data is the integrated sold data (as COUPLING setting)
%2 … 500
Data is as Hn but expressed as a percentage of the fundamental
%S2 … 500
Data is as Hn but expressed as a percentage of the ACDC amplitude
THC
Total Harmonic Current (only valid when used with AMPS data for a
channel)