11
counteract the reaction.
Note:
Sometimes the power tool does not begin the striking the stroke even the motor keep running,
because oil inside become thick. If the power tool is used at a low temperature, or it is used after
a long idle time, this demolition hammer should be kept running for above 5 minutes to warm up.
GREASE AND OIL FILLING
Warning!
Pull plug from power before any operations.
Demolition hammer mechanical part is easy to get worn and lose impact energy if
without enough lubrication, recommend filling grease and oil after 6 months usage. The
steps as follows:
图
1
图
2
图
3
图
4
图
5
图
6
图
7
图
8
5. Maintenance