![Xinje DS2-20P7-AS Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/xinje/ds2-20p7-as/ds2-20p7-as_user-manual_3448033043.webp)
41
ditto
30
/TGON rotation checking, ditto
-
※
2
※
4
●
31
/S-RDY ready, ditto
-
※
2
※
4
●
32
/CLT torque limit, ditto
-
※
2
※
4
●
33
/VLT speed limit checking, ditto
-
※
2
※
4
●
34
/BK brake interlock, ditto
-
※
2
※
4
●
35
/WARN warn, ditto
-
※
2
※
4
●
36
/NEAR near, ditto
-
※
2
※
4
●
37
/ALM alarm, ditto
-
※
2
※
4
●
38
/Z Z signal of encoder, ditto
-
※
2
※
4
●
※
1
:
the default value of input terminals, please refer to table 2.
※
2
:
the default value of output terminals, please refer to table 4.
※
3
:
the input terminal distributions please refer to table 1.
※
4
:
the output terminal distributions please refer to table 3.
Table 1: Input signal distributions
Input terminal parameters
Servo drive
Range
P5-10~P5-24
DS2-20P2-AS
DS2-20P4-AS
DS2-20P7-AS
n.0000~n.0005
n.0010~n.0015
The range is different as the input terminals of servo drive.
Table 2: default settings of input terminals
SI1
SI2
SI3
SI4
SI5
Содержание DS2-20P7-AS