![Xinje DS2-20P7-AS Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/xinje/ds2-20p7-as/ds2-20p7-as_user-manual_3448033038.webp)
36
15
First segment command filter
time
0.1ms
0
0
~
65535
○
P2-16~P2-90 are 2~16 segment parameters, P2-91~P2-93 are reserved.
94
The times pass Z phase signal
after leaving the limit switch
times
2
1~65535
○
95
The speed close to the proximity
switch
0.1rpm
600
0~50000
○
96
The speed leave the proximity
switch
0.1rpm
100
0~50000
○
4. Speed control P3 (address: 0300
~
03FF
)
P3
-
Name
Unit
Default
value
Range
Effective
time
00
Analog value of rated
speed
0.01V
1000
150
~
3000
○
01
Internal speed 1
rpm
100
-5000
~
+5000
√
02
Internal speed 2
rpm
200
-5000
~
+5000
√
03
Internal speed 3
rpm
300
-5000
~
+5000
√
04
JOG speed
rpm
100
0
~
1000
√
05
Acceleration time of soft
start
1ms
0
0
~
65535
○
06
Deceleration time of soft
start
1ms
0
0
~
65535
○
07
Speed command filter
time
0.01ms
0
0
~
65535
○
08
Speed feedback filter time 0.01ms
20
0
~
65535
○
09
Max speed limit (MAX
rpm
Different 0
~
5000
●
Содержание DS2-20P7-AS
Страница 1: ...Wuxi Xinje Electric Co Ltd DS2 series servo drive Manual Data No SC209 20110412 1 0...
Страница 2: ...2...
Страница 13: ...11 Type LA Normal With brake MS 60ST M01330 20P4 146 189...
Страница 14: ...12 80 series motor installation dimensions Unit mm Type LA Normal With brake MS 80ST M02430 20P7 150 191...
Страница 16: ...14 Wiring 1 Main circuit...
Страница 48: ......