background image

4.2 Block Diagram of Integrated WDM 

WD 1543

WD 1543

LT

E

D

F

A

-1550

C

R

P

PON

131 0nm

15 50n m

149 0nm

 

4.3 Front/Back Panel Drawing   

 

5. TECHNICAL PARAMETERS

 

5.1 Technical Parameters 

Item 

Unit 

Technical Parameter 

Remark 

Operating bandwidth 

nm 

1540- 1565 

 

Optical input power range 

dBm 

-5- +10 

Suggested optical input power 

0 - +3dBm 

Noise Figure(NF) 

dB 

3.8~5.5 

+3dBm@1550nm 

Return loss 

Input 

dB 

≥ 45 

 

Output 

dB 

≥ 45 

 

Pump leakage power 

Input 

dBm 

≤-30 

 

Output 

dBm 

≤-30 

 

Gain flatness 

dB 

±0.3 

 

Optical output power stability 

dB 

±0.5 

 

Polarization Sensitivity 

dB 

0.2 

 

Polarization mode dispersion 

ps 

0.5 

 

Optical connector(IN/OUT) 

 

FC/APC or SC/APC or E2000 

 

Working pump quantity 

pcs 

1~3 

 

 

Содержание EDFA-1550-X x X-HP-1U

Страница 1: ...EDFA 1550 X x X HP 1U High Power Optical Amplifier USER GUIDE HANGZHOU XINHAO TECHNOLOGY CO LTD 2014 9 V6 52...

Страница 2: ...2 PRODUCT FEATURE 1 3 APPLICATION 2 4 PRODUCT STRUCTURE DIAGRAM 2 5 TECHNICAL PARAMETER 6 OPERATION INSTRUCTION 5 7 NETWORK MANAGEMENT APPLICATION 8 8 NOTES ABOUT OPTICAL CONNECTION 10 9 OTHER NOTE 11...

Страница 3: ...nd then developing erbium ytterbium co doped double clad fiber amplifier which is fit to CATV system to adapt current require of FTTH and FTTB This series of products produced by JDSU and Lumics etc t...

Страница 4: ...it helps greatly to cooling and replacement Besides it can also make double power supply cold heat backup 2 6 Adjustable Output Power It can adjust the range of output optical power downwards 3dB it...

Страница 5: ...dwidth nm 1540 1565 Optical input power range dBm 5 10 Suggested optical input power 0 3dBm Noise Figure NF dB 3 8 5 5 3dBm 1550nm Return loss Input dB 45 Output dB 45 Pump leakage power Input dBm 30...

Страница 6: ...HP 1U 33 1 33 FC APC or SC APC or E2000 EDFA 1550 2 24 HP 1U 27 2 24 FC APC or SC APC or E2000 EDFA 1550 2 25 HP 1U 28 2 25 FC APC or SC APC or E2000 EDFA 1550 2 26 HP 1U 29 2 26 FC APC or SC APC or...

Страница 7: ...shows SYS NORMAL V6 5 6 2 Product Type Figure 2 in page 1 1 6 3 Product Serial Number Figure 1 page 2 6 4 Optical Power Input Figure 1 page 3 Displaying the current optical power input When the optic...

Страница 8: ...erature 6 8 4 Laser Cooling Current in Figure 2 7 4 In order to ensure the internal temperature of laser range from 20 to 30 we should provide Thermoelectric cooling device a certain amount of operati...

Страница 9: ...9 1 When using a single machine to ignore this menu function 6 10 2 An alarm of master and spare configurated logic Figure 4 9 2 When using a single machine to ignore this menu function 6 10 3 An alar...

Страница 10: ...machine is less than setting value as figure 5 A 3 When the former is normal and the latter is adjusted the alarm is stopped 6 11 5 Setting of LCD Back Light setting method ibid 6 11 6 Restore Factor...

Страница 11: ...work management system However the device s RJ45 or RS232 interface is basically vacant and cannot achieve the network management functions Our company is the well known manufacturers in the cable bro...

Страница 12: ...ope at 100 times 200 times to check the cleanliness of fiber optic connector surface or blemish Pay attention to maintaining the fiber optic connectors is clean Fiber optic connectors flange is clean...

Страница 13: ...laser transmitter enter the work state because the light signal input pump light input is quite high light output for pump light the eye cannot look directly at the light input from the back panel of...

Страница 14: ...please attach the device model serial number and return reasons As for freight if the product under warranty time the customer just need to pay one way freight Concerning to correct freight is higher...

Отзывы: